Table 2 Simulation Parameters.

From: GrCRA PCRTAM net based hybrid approach for intelligent control and optimal power management in renewable integrated power distribution systems

Parameter

Value

Description

PV System Size

5 kW

Typical capacity for distribution-level microgrids; balances feasibility with real-world residential/community applications

Battery Capacity

3.5 kWh

Matches common lithium-ion storage modules; practical size for microgrid applications

Battery SoC Limits

30–80%

Recommended by ageing studies to avoid deep discharge/overcharge and extend cycle life

Supercapacitor Capacity

1 kWh

Smaller size reflects SC’s role as a fast-response buffer for transients rather than bulk storage.

Load Profile

Residential–commercial daily profile (scaled IEEE test case)

Provides realistic demand variations for predictive testing

Simulation Time Step

1 min

Balances accuracy in capturing fluctuations with computational efficiency

Optimization Population Size

30

Ensures sufficient diversity; larger values gave no significant performance gain

Optimization Iterations

100

Stable convergence achieved; higher iterations only increased computation

PCRTAM-Net Learning Rate

0.001

Cross-validation showed better accuracy at a lower rate without divergence

PCRTAM-Net Epochs

50

Prevents overfitting while ensuring adequate training

PCRTAM-Net Batch Size

64