Table 2 Results of uniaxial failure tests on core samples.

From: Field test and numerical simulation study on bonding performance of high-strength steel anti-floating anchor rod under rotary jet grouting construction

Compressive strength/MPa

Average value/MPa

Variance

Grouting method

1

2

3

20.9

20.6

19.9

20.5

0.26

Grouting

20.5

20.1

20.1

20.2

0.05

Rotary jet grouting