Table 5 Measured vs. calculated effective modulus Ey and permeability ky after grouting.
Mixture ratio | 1:0.25 | 1:1 | 1:4 | |||
|---|---|---|---|---|---|---|
Measured | Calculated | Measured | Calculated | Measured | Calculated | |
Ey (Mpa) | 38.26 | 34.88 | 93.47 | 101.39 | 139.24 | 128.85 |
Error | − 8.83% | + 8.47% | − 7.46% | |||
Ey (Mpa) | 46.11 | 48.25 | 87.64 | 82.37 | 132.33 | 141.52 |
Error | + 4.64% | − 6.01% | + 6.94% | |||
ky × 10-7 m/s | 5.35 | 5.53 | 3.49 | 3.13 | 1.29 | 1.34 |
Error | + 3.36% | − 10.42% | + 4.16% | |||
ky × 10-7 m/s | 3.73 | 3.48 | 4.78 | 5.01 | 1.43 | 1.37 |
Error | − 6.83% | + 4.75% | − 3.66% | |||