Table 3 Ablation study results.

From: Cable partial discharge identification network based on adaptive residual diffusion denoising and morphological attention

Method

AR

DM

Accuracy(%)

Baseline model

—

—

75.81

WT

—

—

86.52

SVD

—

—

80.25

PCA

—

—

82.31

ARDDMA-net

—

√

91.34

√

—

81.44

√

√

98.36