Table 4 Ablation study results for variable contribution analysis.

From: Deep learning-based multi-parameter coupling compensation algorithm for clamp-on gas metering systems

Configuration

Temperature (T)

Pressure (P)

Density (ρ)

Temporal component

Average error (%)

RMSE (%)

All Variables

0.52

0.43

Exclude T

1.23

0.89

Exclude P

1.87

1.34

Exclude ρ

1.65

1.12

No Temporal

2.31

1.78

LSTM Only

0.89

0.67

CNN Only

1.05

0.81