Table 3 Displacements and member forces at the central girder under dead loads.

From: Deep learning-based framework for time-dependent reliability analysis of a cable-stayed bridge with corroded PSC box girders under gravity loads

Software

Disp-z (m)

Axial force (Fx) (kN)

Moment (My) (kN∙m)

Moment (Mz) (kN∙m)

OpenSees

− 0.163

− 75,230

27,259

38.4

MIDAS/CIVIL

− 0.158

− 74,452

26,941

32.9