Table 6 CCD matrixes for the experimental design and the responses for COD removal.
Runs | Factor 1 | Factor 2 | Factor 3 | Factor 4 | Removal Efficiency (%) | ||
|---|---|---|---|---|---|---|---|
A: pH | B: Time | C: Dose | D: Speed | Actual | Predicted | Residuals | |
1 | 6 | 90 | 10 | 200 | 91.0 | 90.93 | 0.07 |
2 | 5 | 120 | 5 | 250 | 75.6 | 75.18 | 0.42 |
3 | 6 | 90 | 10 | 250 | 85.5 | 85.39 | 0.11 |
4 | 6 | 90 | 10 | 200 | 91.3 | 90.93 | 0.37 |
5 | 7 | 60 | 15 | 150 | 81.9 | 82.14 | −0.24 |
6 | 6 | 90 | 15 | 200 | 88.9 | 88.66 | 0.24 |
7 | 7 | 60 | 5 | 150 | 80.3 | 79.96 | 0.34 |
8 | 6 | 90 | 10 | 200 | 90.9 | 90.93 | −0.03 |
9 | 6 | 90 | 10 | 200 | 91.3 | 90.93 | 0.37 |
10 | 6 | 90 | 5 | 200 | 85.9 | 86.29 | −0.39 |
11 | 7 | 120 | 15 | 150 | 79.1 | 79.56 | −0.46 |
12 | 5 | 90 | 10 | 200 | 87.4 | 87.80 | −0.40 |
13 | 7 | 60 | 5 | 250 | 78.4 | 78.74 | −0.34 |
14 | 6 | 120 | 10 | 200 | 88.9 | 88.90 | 0.00 |
15 | 7 | 120 | 5 | 150 | 78.2 | 77.91 | 0.29 |
16 | 5 | 60 | 15 | 250 | 76.5 | 76.61 | −0.11 |
17 | 5 | 120 | 15 | 250 | 77.2 | 77.74 | −0.54 |
18 | 7 | 60 | 15 | 250 | 80.5 | 80.39 | 0.11 |
19 | 5 | 60 | 5 | 250 | 73.8 | 73.53 | 0.27 |
20 | 6 | 90 | 10 | 200 | 90.6 | 90.93 | −0.33 |
21 | 6 | 60 | 10 | 200 | 89.2 | 89.36 | −0.16 |
22 | 6 | 90 | 10 | 200 | 90.8 | 90.93 | −0.13 |
23 | 7 | 120 | 15 | 250 | 79.8 | 79.55 | 0.25 |
24 | 6 | 90 | 10 | 150 | 88.2 | 88.47 | −0.27 |
25 | 5 | 120 | 15 | 150 | 83.2 | 82.68 | 0.52 |
26 | 7 | 90 | 10 | 200 | 89.1 | 88.85 | 0.25 |
27 | 5 | 60 | 15 | 150 | 83.4 | 83.28 | 0.12 |
28 | 5 | 60 | 5 | 150 | 79.6 | 79.68 | −0.08 |
29 | 7 | 120 | 5 | 250 | 78.1 | 78.42 | −0.32 |
30 | 5 | 120 | 5 | 150 | 79.3 | 79.60 | −0.30 |