Table 3 Arterial radius and flow volume measurements from PC-MR and TOF-MRA, as detailed in Fig. 3c, using the long segment method.
From: Arterial flow volume measurement using signal intensity gradient versus phase contrast
Arteries | Radius, mean ± SD, mm | P | |
|---|---|---|---|
PC-MR | TOF-MRA | ||
Right ICA | 2.42 ± 0.63 | 2.35 ± 0.22 | 0.654 |
Left ICA | 2.72 ± 0.77 | 2.45 ± 0.37 | 0.199 |
Right VA | 1.80 ± 0.30 | 1.68 ± 0.37 | 0.294 |
Left VA | 1.84 ± 0.53 | 1.75 ± 0.48 | 0.606 |
Flow volume, mean ± SD | |||
|---|---|---|---|
PC-MR, ml/sec | TOF-MRA, SIG·cm3 | ||
Right ICA | 3.11 ± 0.76 | 2.66 ± 1.00 | 0.071 |
Left ICA | 3.55 ± 1.04 | 2.93 ± 0.88 | 0.026 |
Right VA | 1.38 ± 0.62 | 1.22 ± 0.69 | 0.393 |
Left VA | 1.36 ± 0.77 | 1.28 ± 0.95 | 0.745 |
Cerebral blood flow | 9.22 ± 2.03 | 7.97 ± 2.26 | 0.045 |