Table 1 Descriptive statistics for overall and festival-specified LAeqcomp, LCeq, LZeq, 63Hz, along with the corresponding counts exceeding WHO- and Belgian guidelines. Data are presented for both compensated (comp) and non-compensated (non-comp) levels, accounting for the use or non-use of hearing protection devices.

From: Large-scale music events can cause subclinical hearing damage

Event (number of dosimeters) [mean exposure duration (h)]

LAeq (dBA) mean (SD)

LAeqcomp (dBA) mean (SD)

LCeq (dBC) mean (SD)

LZeq, 63Hz mean (SD)

Number of 15-m intervals

 > 100 dBA (WHO) (non-comp)

 > 102 dBA (Bel) (non-comp)

 > 100 dBA (WHO) (comp)

 > 102 dBA (Bel) (comp)

All (39)10

100 (4)

93 (10)

113 (6)

112 (7)

1586

634 (40%)

429 (27%)

463 (29%)

331 (21%)

1 (7) [18.1]

102 (1)

102 (1)

117 (1)

116 (2)

501

283 (56%)

217 (43%)

283 (56%)

217 (43%)

2 (7) [7.1]

98 (1)

88 (9)

110 (1)

109 (1)

196

63 (32%)

26 (13%)

20 (10%)

7 (4%)

3 (5) [7.2]

92 (3)

91 (3)

100 (2)

97 (1)

141

1 (1%)

0 (0%)

0 (0%)

1 (1%)

4 (7) [6.3]

102 (2)

97 (8)

114 (1)

112 (1)

173

89 (51%)

61 (35%)

53 (31%)

33 (19%)

5 (6) [10.8]

101 (3)

94 (15)

117 (4)

117 (4)

256

94 (37%)

62 (24%)

82 (32%)

53 (21%)

6 (7) [11.5]

100 (1)

87 (10)

116 (1)

116 (2)

319

104 (33%)

63 (20%)

25 (8%)

20 (6%)