Table 9 ANOVA results of the mathematical model created for Ra.

From: Parametric optimization of graphite powder-mixed electrical discharge machining of Ni-Cr dental alloy by response surface methodology

Source

Degree of freedom

Adjusted sum of squares

Adjusted mean squares

F-value

P-value

Model

12

46.635

3.886

25.59

0.001

Linear

4

34.305

8.576

56.47

0

I

1

30.550

30.550

201.17

0

Ton

1

1.669

1.669

10.99

0.021

Toff

1

0.256

0.256

1.68

0.251

Dielectric

1

3.371

3.371

22.19

0.005

Square

3

5.148

1.716

11.30

0.012

I 2

1

4.307

4.370

28.78

0.003

Ton2

1

0.442

0.442

2.91

0.149

Toff2

1

0.307

0.307

2.02

0.215

2-Way interaction

5

5.990

1.198

7.89

0.020

I*Ton

1

3.720

3.720

24.50

0.004

I*Toff

1

1.092

1.092

7.19

0.044

I*Dielectric

1

1.187

1.187

7.81

0.038

Ton*Dielectric

1

0.220

0.220

1.45

0.282

Toff*Dielectric

1

0.188

0.188

1.24

0.316

Error

5

0.759

0.152

  

Total

17

47.394