Table 3 Proposed conversion functions between cubes and cylinders for UHPC compressive strength.
convert 50-mm cubes to 100-mm cubes | convert 50-mm cubes to 75-mm cylinders | convert 100-mm cubes to 75-mm cylinders | |||||||
|---|---|---|---|---|---|---|---|---|---|
Function | p-value | R2 | Function | p-value | R2 | Function | p-value | R2 | |
Linear with intercept | 0.8x + 12.1 | < 0.001 < 0.001 | 0.86 | 1.1x + 6.2 | 0.022 < 0.001 | 0.90 | 1.3x − 5.7 | 0.0144 < 0.001 | 0.94 |
Linear without intercept | 0.90x | < 0.001 | 0.83 | 1.10x | < 0.001 | 0.89 | 1.20x | < 0.001 | 0.94 |
Power function | 1.50 × 0.9 | 0.0352 < 0.001 | 0.87 | 1.04 × 1.03 | 0.733 < 0.001 | 0.91 | 0.80 × 1.1 | 0.0052 < 0.001 | 0.96 |