Table 7 Energy intensity comparison for removing 0.001056 kg formaldehyde*
From: Evaluating the efficiency of formaldehyde degradation from aqueous environment by sonozone technique
Process | Total energy (kJ) | Energy per kg formaldehyde (kJ/kg) |
|---|---|---|
US (150 W, 32 min, 0.001056 kg formaldehyde) | 288 | 273,000 |
Ozonation (83 kJ total, 32 min, 0.6 mg/min L, 20% excess, 100 L, 0.00132 kg frmaldehyde) | 83 | 62,879 |
Sonozone (0.012124 kg formaldehyde) | 371 | 30,601 |