Table 6 Comparison of diagnostic efficiency of each examination method.
Diagnostic method | Accuracy (%) | Sensitivity (%) | Specificity (%) | Youden index |
|---|---|---|---|---|
Smear cytology | 45.38 | 40.63 | 65.22 | 0.056 |
Liquid-based cytology | 61.34 | 61.46 | 69.57 | 0.279 |
FDS | 79.00 | 90.63 | 73.91 | 0.602 |
P value | 0.001 | 0.001 | 0.814 | - |