Table 3 The sorption (µg/mm3) after 30 days in different storage media: alcohol and saliva. Different lower-case letters indicate statistically significant differences between materials stored in alcohol.

From: Mechanical properties of modern restorative “bioactive” dental materials - an in vitro study

Material

Mean value of sorption (µg/mm3) ± SD

Storage medium

Alcohol

Saliva

Activa Bioactive Restorative

106.49 ± 7.85 a

46.27 ± 2.86

Beautifil Flow Plus F00

39.83 ± 1.80

38.52 ± 2.28

Beautifil Flow Plus F03

37.15 ± 1.57

33.88 ± 1.12

Predicta Bulk Bioactive

16.90 ± 1.18 b

14.14 ± 1.83

Filtek Supreme Flow

24.90 ± 1.60 b

24.48 ± 1.74