Table 3 I, II and III point injection-molding parameter results.

From: Quality optimization of liquid silicon lenses based on sequential approximation optimization and radial basis function networks

Item

Filling time (s)

Melt temperature (°C)

Curing pressure (MPa)

Curing time (s)

Mold temperature (°C)

AverageVon-Mises thermal stress (Mpa)

Volume Shrinkage(%)

I

1.94

26.45

33.97

19.99

150.04

18.42

2.78

II

2.23

29.20

39.34

19.49

150.12

17.72

3.75

III

1.57

27.18

28.79

20.02

150.00

16.72

4.14