Table 3 The control parameters used in the charging/discharging processes of the FESS-UPS.

From: State switch control of magnetically suspended flywheel energy storage system in uninterrupted power supply system

Control units

Expression

Control units

Expression

Voltage compensator

Gv(s)

\({G_v}\left( s \right)=30+5\frac{1}{s}+2\frac{{100}}{{1+100\frac{1}{s}}}\)

d-axis current compensator

Gid(s)

\({G_{id}}\left( s \right)=10+\frac{1}{s}+0.5\frac{{100}}{{1+100\frac{1}{s}}}\)

Speed compensator

Gω(s)

\({G_\omega }\left( s \right)=20+5\frac{1}{s}+0.5\frac{{100}}{{1+100\frac{1}{s}}}\)

q-axis current compensator

Giq(s)

\({G_{iq}}\left( s \right)=15+2\frac{1}{s}+0.5\frac{{100}}{{1+100\frac{1}{s}}}\)