Table 4 The reference parameters were extracted from the EIS fitting plots for PKO samples with varying concentrations.

From: Investigation and evaluation of the efficiency of palm kernel oil extract for corrosion inhibition of brass artifacts

Sample

Rs (Ω)

Error%

Rp (Ω)

Error%

CPE1-T

Error%

CPE1-P

Error%

Wo1-R

Error%

Wo1- T

Error%

Wo1-P

Error%

Chi-squared

A

1%PKO

7.104

620

0.00020529

0.7701812

2710

4.004

0.56636

0.0024493

1.2%

1.9%

3.4%

0.7%

2.17%

3.71%

3.2%

B

3%PKO

5.32

503.7

0.00039787

0.7036911

1913

4.333

0.54813

0.011338

2.8%

4.5%

7.5%

1.7%

2.3%

4.2%

3.2%

C

5%PKO

4.186

498.6

0.00069834

0.69008

1343

4.788

0.55316

0.01853

3.9%

7.8%

1.0%

2.5%

2.0%

3.9%

2.7%

D

7%PKO

7.69

509.1

0.00060333

0.64772

1810

5.802

0.51893

0.004334

1.7%

4.5%

4.4%

1.1%

1.9%

4.0%

2.1%