Table 8 Maximum circumferential stresses and allowable stresses of steel casings with a length of 15 m.
Wall thicknesses of steel casings (mm) | Maximum circumferential stress (MPa) | Allowable stress (MPa) |
|---|---|---|
22 mm | 278.30 | 65.7 |
27 mm | 236.03 | 67.3 |
31 mm | 122.90 | 68.7 |
34 mm | 84.20 | 70.0 |
36 mm | 68.97 | 70.8 |