Table 2 Limit values of displacement angles for different Building structure systems.
From: Design of displacement-based viscous damper damping structures
Building structure | Displacement angle limit value |
|---|---|
Conversion layer | 1/1000 |
Shear wall | 1/1000 |
Tube in tube | 1/1000 |
Frame | 1/550 |
Core tube | 1/800 |