Table 11 NOx conversion efficiency and statistical analysis under different catalyst loadings.
Catalyst loading (g/m2) | NOx conversion efficiency (%) | Mean value (%) | SE (%) | p-value (ANOVA Analysis) |
|---|---|---|---|---|
250 | 23.5, 24.0, 23.8 | 23.77 | ± 0.25 | < 0.01 |
350 | 32.1, 32.5, 32.3 | 32.30 | ± 0.20 | < 0.01 |
500 | 41.5, 42.3, 43.1 | 42.30 | ± 0.80 | < 0.01 |