Table 3 Comparison of macular ganglion cell layer (GCL) thickness (μm) values between PEX and control groups.

From: Retinal neurodegeneration, neuroretinal rim analysis and choroid thickness in pseudoexfoliation syndrome with spectral domain optical coherence tomography

Variable

PEX

(n = 38)

Control

(n = 22)

p

Total GCL

47.5 ± 5.5

50.5 ± 5.2

0.039*

Superior GCL

48.5 ± 5.9

52.0 ± 3.9

0.016*

Temporal-superior GCL

44.1 ± 6.8

46.0 ± 6.1

0.267

Temporal-inferior GCL

48.1 ± 5.7

49.8 ± 6.5

0.298

Inferior GCL

48.1 ± 5.5

52.1 ± 5.2

0.007*

Nasal-inferior GCL

48.5 ± 5.3

52.2 ± 6.1

0.017*

Nasal-superior GCL

47.8 ± 6.8

52.0 ± 5.4

0.017*

  1. Values are expressed as mean ± SD.
  2. PEX pseudoexfoliation, GCL ganglion cell layer.
  3. *Statistically significant p values.