Table 3 Analysis of dry-bulb temperature deviation in temperature stabilization points of bulk curing barn with different types of biomass combustion equipment.
From: Analysis of curing effect of bulk curing barns with different types of biomass combustion equipment
Treatment | Dry-bulb temperature stabilization point/℃ | ||||||||
|---|---|---|---|---|---|---|---|---|---|
36 | 38 | 40 | 42 | 45 | 48 | 54 | 60 | 68 | |
T1 | − 0.3 ± 0.1bc | 0.4 ± 0.1a | − 0.3 ± 0.1b | − 0.4 ± 0.2b | − 0.5 ± 0.1b | − 0.6 ± 0.1d | − 0.4 ± 0.1b | − 0.2 ± 0.2b | − 0.6 ± 0.2c |
T2 | − 0.2 ± 0.0b | − 0.2 ± 0.1c | − 0.4 ± 0.2bc | 0.2 ± 0.1a | − 0.5 ± 0.1b | − 0.5 ± 0.1d | 0.3 ± 0.1a | − 0.4 ± 0.2b | − 0.4 ± 0.1bc |
T3 | − 0.4 ± 0.1c | 0.5 ± 0.1a | − 0.4 ± 0.1c | − 0.3 ± 0.2b | − 0.6 ± 0.1b | 0.5 ± 0.2a | − 0.7 ± 0.2c | − 0.4 ± 0.2b | − 0.5 ± 0.1bc |
T4 | 0.2 ± 0.1a | 0.1 ± 0.1b | 0.1 ± 0.1a | 0.2 ± 0.2a | 0.3 ± 0.1a | 0.2 ± 0.1b | 0.2 ± 0.1a | − 0.2 ± 0.2b | − 0.4 ± 0.2b |
T5 | 0.3 ± 0.1a | 0.1 ± 0.2b | − 0.2 ± 0.1b | 0.3 ± 0.2a | 0.4 ± 0.1a | − 0.2 ± 0.1c | 0.2 ± 0.2a | 0.3 ± 0.0a | 0.5 ± 0.1a |