Table 1 Furnace tube simulation scheme diagram.
Number | Distribution length/mm | Output power ratio | Heating wire volumetric heat generation rate /103 W/m3 |
|---|---|---|---|
A1 | 100:100:100 | 1:1:1 | 300:300:300 |
A2 | 100:100:100 | 1.25:1:1.25 | 375:300:375 |
A3 | 100:100:100 | 1.5:1:1.5 | 450:300:450 |
A4 | 100:100:100 | 1.75:1:1.75 | 525:300:525 |
A5 | 100:100:100 | 2:1:2 | 600:300:300 |
B1 | 125:50:125 | 1:1:1 | 300:300:300 |
B2 | 125:50:125 | 1.25:1:1.25 | 375:300:375 |
B3 | 125:50:125 | 1.5:1:1.5 | 450:300:450 |
B4 | 125:50:125 | 1.75:1:1.75 | 525:300:525 |
B5 | 125:50:125 | 2:1:2 | 600:300:300 |
C1 | 75:150:75 | 1:1:1 | 300:300:300 |
C2 | 75:150:75 | 1.25:1:1.25 | 375:300:375 |
C3 | 75:150:75 | 1.5:1:1.5 | 450:300:450 |
C4 | 75:150:75 | 1.75:1:1.75 | 525:300:525 |
C5 | 75:150:75 | 2:1:2 | 600:300:300 |