Table 4 Multi-zone high-temperature furnace supplementary test point temperature field data sheet.
Axial coordinate | 200℃ | 400℃ | 600℃ | 800℃ | 1000℃ | 1200℃ |
|---|---|---|---|---|---|---|
-50 | 1.306 | 1.271 | 1.352 | 0.587 | 0.287 | -0.242 |
-40 | 0.835 | 0.895 | 0.745 | 0.238 | 0.208 | -0.128 |
-30 | 0.336 | 0.423 | 0.584 | 0.151 | -0.004 | -0.137 |
-20 | -0.003 | 0.064 | 0.230 | 0.078 | -0.079 | -0.077 |
-10 | -0.105 | -0.097 | 0.000 | 0.065 | -0.038 | -0.014 |
0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
10 | 0.278 | 0.195 | 0.179 | -0.061 | 0.093 | 0.022 |
20 | 0.593 | 0.479 | 0.418 | -0.112 | 0.250 | 0.129 |
30 | 0.838 | 0.645 | 0.482 | -0.203 | 0.505 | 0.297 |
40 | 0.676 | 0.556 | -0.901 | -0.490 | 0.665 | 0.437 |
50 | -1.350 | -0.979 | -1.580 | -1.462 | -0.073 | 0.247 |