Abstract
Autonomous AI for diabetic eye examination is among the most validated and trusted medical AI systems, supported by extensive real-world evidence demonstrating safety, efficacy, improved outcomes, increased productivity, and cost savings. Yet its adoption remains limited. In contrast, commercially available off-the-shelf generative AI models (OTSAIs) are being rapidly tested in medical settings despite a lack of such real-world validation. These models have shown strong performance on medical reasoning tasks, prompting interest in their potential for clinical deployment. We evaluated four OTSAIs—GPT-4o and GPT-4o-mini (OpenAI, San Francisco, CA), Grok (xAI, San Francisco, CA), and Gemini (Google, Mountain View, CA)—on a specific diagnostic task: diabetic eye examination. The OTSAIs were bundled to ensure consistency, and performance was assessed using a level 3 reference standard, the publicly available Messidor-2 dataset. GPT-4o achieved the highest area under the receiver operator characteristic curve (AUC), 0.83. Grok achieved 0.63, and AUC was not calculable for Gemini. The AUC of retina specialists on the same task was estimated at 0.94, so the emergent performance of OTSAIs does not match that of clinical experts, nor does it approach FDA endpoints for consideration as a medical device. Nevertheless, as the performance of these OTSAIs approaches theoretical limits in the future, there might be a regulatory path through task-specific licensing by State Medical Boards for specific clinical tasks. This path may be modeled after licensing for physician assistants, where trust in the bundled OTSAI, to be used in an assistive fashion, is achieved through rigorous validation for safety and efficacy according to widely accepted regulatory considerations for both patient-facing AI, as well as for SaMD processes.
Similar content being viewed by others
Introduction
Autonomous artificial intelligence (AI) for the diabetic eye examination is one of the most validated and widely adopted medical AI use cases in the United States1. Real-world deployments, supported by randomized controlled trials and observational studies, have demonstrated improved patient outcomes2,3, expanded access to care, reduced health disparities4, and increased clinician productivity5 at lower cost6,7. Notably, this specific autonomous AI system also cleared critical ethical, regulatory, reimbursement, and workflow hurdles—establishing a viable path for future medical AI deployment7,8,9. Given these successes, one might expect other AI systems to quickly follow. Yet this has not occurred. Even the most widely used medical AI devices today reach fewer than 1% of the patients who could benefit10.
Trust in such AI requires rigorous validation along with substantial effort and risk to design, build, and validate autonomous AI models in alignment with the U.S. Food and Drug Administration’s (FDA) regulatory total product lifecycle (TPLC) framework for SaMD. Ensuring trust requires demonstrating high diagnostic accuracy9, mitigating bias11, and ensuring clinical interpretability8. Although ophthalmic foundation models offer promise for more rapid iteration through (implicit) priors12, none have yet advanced to FDA-cleared medical devices. At the same time, general-purpose, unsupervised (with respect to medical tasks), off-the-shelf multimodal AI models (OTSAIs)—such as ChatGPT (OpenAI, San Francisco, CA), Gemini (Google, Mountain View, CA), and Grok (xAI, San Francisco, CA)—have advanced rapidly in their capabilities. These OTSAIs are not trained for any specific medical task, nor are they marketed as medical devices. Thus, they differ fundamentally from purpose-built clinical models. They have demonstrated strong performance on standardized medical reasoning exams despite lacking explicit clinical training, including the Medical College Admission Test (MCAT), the United States Medical Licensing Examination (USMLE), and the Ophthalmic Knowledge Assessment Program (OKAP) Board preparation examination13,14,15. Early investigation has also looked at accuracy on medical imaging tasks16. However, none of these models has been evaluated as would be required if it were a medical device—such as through Good Clinical Practice (GCP)-compliant clinical trials using a level 1 reference standard within a real-world workflow, along with the many other requirements that have become standard for autonomous diagnostic AI devices8.
Because OTSAIs are not designed or trained for specific diagnostic tasks, their performance on such tasks is an emergent behavior, i.e., task performance is not a result of deliberate training or model optimization17. Although these unsupervised foundation models have likely ingested biomedical content during training, they were not deliberately trained or optimized for the diabetic retinopathy task. Thus, any above-chance performance on this task can be viewed as an emergent behavior rather than the result of task-specific training. In this way, OTSAIs are similar to physicians and other clinicians, who are regulated through a licensing process by State Medical Boards, in the US and many other jurisdictions. Potentially, OTSAIs might qualify for a similar licensing process, coupled with validation for specific tasks to assist clinicians.
However, to our knowledge, no OTSAI has been evaluated on a clinical task using performance standards consistent with established regulatory expectations for medical devices. Such an evaluation requires a clinical domain with well-defined, stakeholder-supported benchmarks—including alignment with developed FDA standards, established workflows, interpretable reference standards, and publicly available datasets. Ophthalmology, specifically the autonomous AI diabetic eye examination, offers a uniquely mature setting for this kind of assessment, with broadly accepted and validated level 3 reference datasets such as ROC and the publicly available Messidor-2 dataset, in combination with a widely supported and documented regulatory process8,18,19,20.
In this study, we evaluate the diagnostic performance of four OTSAIs to assess whether such OTSAIs could now, or perhaps in the future, meet the regulatory performance thresholds required of autonomous diagnostic devices aligned with current FDA standards.
Results
Reportability across models and prompting strategies
All containerized OpenAI and xAI models—GPT-4o, GPT-4o-mini, and Grok-2-vision—successfully returned valid, structured outputs in 100% of cases across the minimal, background, and few-shot prompting strategies. In contrast, Gemini-1.5-pro exhibited lower reportability, returning analyzable outputs in 85% of cases with minimal prompting, 89% with background prompting, and 100% with few-shot prompting.
Receiver operating characteristic (ROC) analysis against a level 3 reference standard
AUC values for all models and prompting strategies are presented in Table 1.
GPT-4o-2024-08-06 achieved the highest AUC overall at 0.83. ROC curves for each model under each prompting strategy are shown in Fig. 1. A representative ROC curve for GPT-4o using background prompting, along with 95% confidence intervals, is shown in Fig. 2, with the selected operating point indicated in red. Sensitivity–specificity pairs for three human expert graders are shown for comparison; the estimated retina specialist AUC on the same dataset was 0.94221.
95% confidence bounds were derived via bootstrapping (2000 stratified samples) using the pROC package in R. The red point marks the model set point at which the lower bound of the 95% confidence interval for sensitivity was at least 80%. The three blue points represent the sensitivity and specificity values for the three expert human graders.
Diagnostic performance compared to the level 3 reference standard
Sensitivity and specificity for each model and prompting strategy are shown in Table 1. GPT-4o-2024-08-06 demonstrated the highest overall performance across models, with comparable results using minimal and background prompting strategies. Across all prompting strategies, this model achieved a maximum sensitivity of 88% and specificity of 63% when using background prompting, as determined at the threshold where the lower bound of the 95% confidence interval for sensitivity exceeded 80%. Sensitivity and specificity for each model and prompting strategy without the set point is shown in Table 2.
False negative patterns and consistency across models
Analysis of false-negative predictions revealed limited overlap across models. Intersection over union (IoU) values for false-negative sets across prompting strategies were 0.35 for GPT-4o-2024-08-06, 0.24 for Grok-2-vision-1212, and 0.19 for GPT-4o-mini, indicating that GPT-4o-2024-08-06 produced the most consistent results across different prompting strategies. Representative false-negative cases for this model are shown in Fig. 3. All false-negative cases are shown in Supplementary Fig. 3.
Discussion
In this study, we found that an off-the-shelf AI model (OTSAI), GPT-4o—despite not being explicitly trained for any medical imaging task—achieved an emergent AUC of 0.83, and a sensitivity of 88% and specificity of 63%, at the threshold meeting a lower bound of 80% sensitivity, against a level 3 reference standard, in detecting more-than-mild diabetic retinopathy. For context, retina specialists achieve an AUC of 0.94 on this same level 3 reference standard, Messidor-221. Thus, OTSAIs still substantially underperform clinical experts. Given that performance against a level 3 reference standard typically overestimates performance against a level 1 standard—as required by the first autonomous-AI pivotal trial—by 10–30%9,11, these OTSAIs also would not meet regulatory thresholds for safety and efficacy as autonomous AI devices. Under current regulatory requirements, autonomous diagnostic AI systems are expected to exceed the lower bound of 80% for both sensitivity and specificity against a level 1 reference standard. It should be noted that the Messidor-2 dataset is publicly available and that it is possible this data was accessed when building the OTSAI. Consequently, our reported AUC, sensitivity, and specificity metrics may be taken as potentially inflated, upper bounds on accuracy.
In addition to substantially higher accuracy against a level 1 reference standard, OTSAIs would also require evaluation for demographic and clinical bias under GCP, adherence to ISO 13485 quality management system (QMS) and IEC 62304 software lifecycle standards, full alignment with the FDA’s TPLC, and many other regulatory guidelines for software as a medical device (SaMD)22. Table 3 lists requirements for an ISO 13485 compliant QMS; this would be a baseline set of standards to claim conformance for an OTSAI bundle for diabetic eye exams.
Analysis of false-negative cases shows these most often occurred in less-severe cases—such as those with single retinal hemorrhages—which are also challenging for human experts (Fig. 3). This pattern may indicate that the model’s perceptual strategy approximates that of human experts, though further analysis into underlying mechanisms is beyond the scope of this pilot study.
This study has several limitations. First, the evaluation was conducted using a publicly available, retrospective dataset (Messidor-2) and a level 3 reference standard. While this standard is often used for benchmarking, it is not a level 1 prognostic standard, such as has been required for regulatory approval of autonomous AI. Such a validation would require a prospective study in a primary care setting with a level 1 reference standard (i.e., using a prognostic reference standard). Thus, the measured level 3 accuracy likely overestimates true performance. Given that multiple level 3 and 4 Messidor-2 standards are publicly available, including through the Kaggle competition website23, and likely the models ingested such data, this may have led to additional overestimation of accuracy. Optimal unbiased performance estimation would require validation on prospectively collected, preregistered, independent, access-controlled datasets—shielded from public exposure—corresponding to level 1–4 reference standards8. This is essential to remove any risk of training data leakage. However, conducting these studies demands substantial resources—often tens of millions of dollars—typically available only to private companies rather than academic research groups. Nonetheless, our open-source codebase and containerized pipeline are designed to support future external validations, which we identify as a priority for subsequent research.
Finally, this study could not evaluate performance in the clinical workflow, which may include operators with lower expertise—as was the case in the first pivotal trial—also likely leading to overestimation. It is important to note that we did not fine-tune or otherwise adapt these models for the task; exploring supervised optimization strategies (and their impact on both diagnostic accuracy and general medical reasoning performance) is beyond the scope of this pilot study. While these unsupervised models were not explicitly trained for our task, we recognize that their training on vast data likely endows them with some relevant knowledge—so their success is “emergent” only in the sense that no task-specific tuning was done. Only performance on retinal images was evaluated, and our findings may not generalize to other clinical domains or imaging modalities. However, autonomous AI for the diabetic eye exam has been a pioneering precedent in real-world implementation of AI, including AI ethics4, liability24, regulation9, RCTs3, and reimbursement7, and thus the policy and deployment considerations may extrapolate more broadly to medical AI. Future work should indeed examine these general-purpose models in additional clinical contexts. Finally, none of the many other requirements for autonomous AI as a medical device were evaluated, including alignment with an ISO 13485 compliant QMS, and the many other requirements for SaMD and AI explained above.
While the OTSAIs do not currently meet the criteria to qualify as regulated medical AI devices, their performance may improve over time and approach its theoretical limit—that of publicly available ophthalmologist performance on such narrowly defined diagnostic tasks. Although not currently clinically viable, OTSAIs already achieve expert-level performance on standardized medical reasoning assessments, including the MCAT, USMLE, and OKAP13,14,15, as well as softer medical competencies such as effective communication, ethics, and empathy13,25.
Looking ahead, as OTSAIs improve, one could envision an alternative regulatory path, through task-specific licensing and monitoring by organizations currently responsible for human expert licensing, such as the Federation of State Medical Boards. Medical professionals are typically regulated through state-based licensure systems, where they are evaluated on competencies including medical school graduation, residency completion, and performance on the medical-reasoning-based examinations (on which OTSAIs also do well), as well as continuing medical education (CME), to ensure that clinicians remain up to date with current standards of care. Importantly, licensed clinicians’ accuracy on specific clinical tasks is considered emergent behavior—i.e., arising from complex adaptive systems without either training nor accuracy assessment for specific diagnostic or therapeutic tasks17. In fact, only under very specific circumstances are physicians and other providers evaluated for diagnostic performance: in scientific studies designed for that purpose, or in malpractice investigations. Prior studies have shown that ophthalmologists’ sensitivity in the diabetic eye exam against level 1 prognostic reference standards range from 30% to 40%26,27, and would thus fail evaluation as a “medical device” under FDA criteria for an autonomous AI system. Under this pathway, OTSAIs would be bundled for a specific clinical task. Bundling would involve scoping and standardization of inputs (prompts and patient data, such as images) and outputs, setting of consistent thresholds, and validation of its performance on general medical tasks, including clinical knowledge and medical reasoning, as set forward previously. But, unlike human clinicians, whose accuracy on diagnostic tasks is assumed to be emergent, licensing for an OTSAI bundle for the diabetic eye exam would require explicit rigorous validation for that specific task to ensure trust in the bundled OTSAI. Such a pathway might parallel the licensing pathway for physician assistants, who are licensed to assist a licensed physician. It is generally accepted that the liability for the performance of medical device based autonomous AI falls on the AI creator24,28,29, and similarly we expect this would be the case for non-device, licensed bundled OTSAIs.
As set forward in the introduction, despite growing evidence—including from randomized controlled trials—that AI systems improve clinical outcomes2,3, increase access, reduce disparities4, enhance clinical productivity5, and lower costs7, the real-world adoption of AI in healthcare remains limited. As of 2025, more than 1000 AI-enabled medical devices have received FDA clearance, yet only a small subset have achieved meaningful uptake in clinical practice1,30. Regulatory complexity, uncertainty, and risk remain key barriers to broader adoption. The alternative licensing pathway could accelerate scalable deployment of bundled OTSAIs for such narrowly defined clinical tasks.
On the other hand, this pathway may not align with the overarching goal of optimizing patient outcomes. Current bioethical frameworks, which emphasize the dyadic physician–patient relationship, rather than centering on patient outcomes, do not adequately capture the broader tradeoffs involved in scaling high-performing autonomous AI31. Holding bundled OTSAIs only to the standard of mimicking average clinician performance—rather than surpassing it, as is the case for autonomous AI medical devices—may limit outcome improvement and essentially provide affordable substitution for clinicians, rather than more affordable care with superhuman accuracy. Autonomous AI devices that demonstrably outperform clinicians on objective clinical tasks may offer greater individual and societal benefit.
We have demonstrated that OTSAIs—despite not being explicitly trained for diagnostic tasks—can achieve reasonable accuracy on the diabetic eye exam, but still substantially underperform clinical experts, and do not meet regulatory standards for FDA-regulated autonomous AI medical devices. As one of the first works to formally evaluate such models, documenting such a “negative” finding, that OTSAIs are not on par with supervised AI, is scientifically meaningful by setting a benchmark clarifying the remaining performance gap. Further, this work provides a regulatory aligned, reproducible evaluation framework for OTSAIs. The publicly available code, including transparent prompt engineering, will facilitate replications of and expansions on our work. Multiple aspects set an example for alignment with regulatory expectations: (i) the use of prespecified operating point selection for sensitivity and specificity metrics; (ii) full adherence to TRIPOD LLM reporting standards; and (iii) explicit mapping of observed performance to FDA’s TPLC and ISO13485 quality management requirements. This study not only provides a confirmation of OTSAI underperformance relative to dedicated, supervised AI but offers a template for future evaluations of general-purpose models across clinical tasks.
While we introduce the concept of licensing OTSAIs, we acknowledge this is untested and that numerous legal and ethical questions remain, including those surrounding liability, bias, and patient benefit. Additionally, it is clear OTSAIs are not currently viable for clinical deployment. This discussion is a speculative and forward-looking conclusion and is intended to prompt proactive consideration of governance, rather than to propose an immediate policy change based on current evidence. Ultimately, any model implemented must be held to standards to avoid unacceptable risk, and outcomes improvement should remain the ultimate yardstick. We do not endorse this licensing approach outright but suggest it as one scenario to consider in view of the pressing need to expand AI access responsibly. Indeed, all stakeholders’ primary goal should be to improve patient outcomes, and delaying access to demonstrably beneficial AI represents a missed opportunity for improving outcomes at scale.
Looking ahead, as OTSAIs increasingly exhibit emergent clinical competencies, an alternative pathway may be needed to balance trust and scalability. A licensing-based framework—modeled after physician assistant licensing by Medical Boards—for bundled OTSAIs performing specific clinical tasks might accelerate deployment and scale the impact of beneficial AI, ultimately improving patient outcomes. Whether pursued through traditional medical device regulation or a licensing model for bundled OTSAIs, either pathway will require evidence of safety and security, in accordance with current regulatory considerations and guidelines. Ensuring trust, while maintaining transparency and accountability, will be essential to differentiate beneficial AI from those that pose unacceptable risk, all in pursuit of the shared goal of massively improving patient outcomes with trusted AI.
Methods
Dataset
For model evaluation, we used the publicly available Messidor-2 dataset, (https://www.adcis.net/en/third-party/messidor2/) which consists of 1748 de-identified macula-centered fundus images from 874 examinations of patients with diabetes. This dataset is available for public, noncommercial use and has previously been described in detail21. The images were acquired with a Topcon TRC NW6 nonmydriatic fundus camera (Topcon USA, Inc). A level 3 reference standard was provided by three clinicians and is also publicly available, defined as the presence or absence of more-than-mild diabetic retinopathy (mtmDR), currently operationalized as ETDRS grading of ≥35 and/or having (clinically significant) macular edema32,33, as per ETDRS. Any ETDRS grading ≥35 implies an International Clinical Diabetic Retinopathy (ICDR) severity scale score ≥2, indicating moderate or severe non-proliferative diabetic retinopathy (NPDR) or proliferative diabetic retinopathy34. Ground truth mtmDR labels were obtained using voting from the blinded grading of each image in the dataset by three world-renowned, expert retina specialists21. The number of patients in the dataset with mtmDR was 190, and the number of patients without mtmDR was 684, corresponding to a prevalence of 21.7%. This study used only publicly available, fully de-identified data (Messidor-2) and therefore did not require institutional review board approval or informed consent.
Each image in the dataset was preprocessed by cropping to the size of the circular retinal image. All images were downsampled to a size of 768 × 768 pixels for consistency of resolution across all models, as models from OpenAI and xAI automatically perform this downsampling prior to image processing.
Models and prompt design
This study retrospectively evaluated existing, publicly available models. Specific, off-the-shelf, commercially available OTSAIs were selected for analysis. The models were “gpt-4o-2024-08-06” and “gpt-4o-mini” from OpenAI, “grok-2-vision-1212” from xAI, and “gemini-1.5-pro” from Google. All models were accessed via the application programming interfaces (APIs) provided using Python version 3.13.0, and all model responses were generated between February 13 and February 20, 2025. For all models, the “temperature” parameter was set to zero to minimize output randomness and promote selection of the most likely token sequence.
Containerization
Each model was containerized as follows: model versions frozen on specific dates were accessed via application programming interfaces, with standardized structured prompts preceding image presentation for grading. Models were given standard instructions to produce responses in JavaScript Object Notation (JSON) format, which was subsequently programmatically post-processed. Three prompting strategies were evaluated across all models, as detailed in Supplementary Fig. 1:
-
Minimal: the model was given basic system instructions and a request to return a Boolean grade for mtmDR in structured JSON.
-
Background: the model was additionally supplied with background on ETDRS scoring definitions for diabetic retinopathy severity.
-
Few-shot: each model was shown every image in our dataset, preceded by question–answer pairs consisting of five images with their ground-truth answers as contextual lead-up to the image being graded.
The desired structured JSON output was a dichotomous true or false value that was compared to the reference standard. Models were prompted to provide a mtmDR grade for every image (no ‘ungradable’ category). Reportability (promptability) was the percentage of queries that resulted in a properly JSON-formatted output. Patients for whom the mtmDR was not returned in properly structured JSON format for each of the two images were not analyzed. Only the properly reported outputs were included in the analyzed data. Sensitivity and specificity were calculated at the subject level (either eye having mtmDR).
ROC analysis
ROC analysis was conducted at the subject level. For models that permitted probability extraction, we estimated confidence by summing likelihood of all tokens corresponding to a “true” Boolean value. These probabilities were then used to generate ROC curves.
For each model, we selected the operating point where the lower bound of the 95% confidence interval for sensitivity was ≥80% and computed the corresponding specificity. Confidence intervals bounds were derived via bootstrapping (2000 stratified samples) using the pROC package. Sensitivity–specificity pairs were also calculated for each of the three human graders by comparing each grader’s annotations against those of the other two, as previously described in ref. 20. An estimated AUC presenting expert human performance was computed based on the area enclosed by these three grader-derived points.
False negative analysis
We identified all false negative cases for the best-performing OTSAI. Among subjects with false negative predictions, we computed the IoU for each model across all prompting strategies to assess consistency in error patterns.
Data availability
The Python, Bash, and R code for this project is open-sourced and can be found at https://github.com/atthewmay/OTSAI_for_mtmDR_screening. The images and reference standard can be downloaded at https://medicine.uiowa.edu/eye/abramoff.
References
Wu, K. et al. Characterizing the clinical adoption of medical AI devices through U.S. insurance claims. NEJM AI 1, AIoa2300030 (2024).
Huang, J. et al. Autonomous artificial intelligence exams are associated with higher adherence to diabetic retinopathy testing in an integrated healthcare system. Invest. Ophthalmol. Vis. Sci. 64, 212 (2023).
Wolf, R. M. Autonomous artificial intelligence increases screening and follow-up for diabetic retinopathy in youth: the ACCESS randomized control trial. Nat. Commun. 15, 421 (2024).
Huang, J. J. et al. Autonomous artificial intelligence for diabetic eye disease increases access and health equity in underserved populations. Npj Digit. Med. 7, 196 (2024).
Abramoff, M. D. et al. Autonomous artificial intelligence increases real-world specialist clinic productivity in a cluster-randomized trial. Npj Digit. Med. 6, 184 (2023).
Wolf, R. M., Channa, R., Abramoff, M. D. & Lehmann, H. P. Cost-effectiveness of autonomous point-of-care diabetic retinopathy screening for pediatric patients with diabetes. JAMA Ophthalmol. 138, 1063–1069 (2020).
Abràmoff, M. D. et al. A reimbursement framework for artificial intelligence in healthcare. NPJ Digit. Med. 5, 72 (2022).
Abràmoff, M. D. et al. Foundational considerations for artificial intelligence using ophthalmic images. Ophthalmology 129, e14–e32 (2022).
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N. & Folk, J. C. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices. NPJ Digit. Med. 1, 39 (2018).
Abramoff, M. D., Dai, T. & Zou, J. Scaling adoption of medical AI—reimbursement from value-based care and fee-for-service perspectives. NEJM AI 1, AIpc2400083 (2024).
Abràmoff, M. D. et al. Mitigation of AI adoption bias through an improved autonomous AI system for diabetic retinal disease. Npj Digit. Med. 7, 1–10 (2024).
Zhou, Y. et al. A foundation model for generalizable disease detection from retinal images. Nature 622, 156–163 (2023).
Kung, T. H. et al. Performance of ChatGPT on USMLE: potential for AI-assisted medical education using large language models. PLOS Digit. Health 2, e0000198 (2023).
Staff, B. ChatGPT Moderately Accurate in Interpreting Ophthalmic Images. https://www.reviewofoptometry.com/article/chatgpt-moderately-accurate-in-interpreting-ophthalmic-images (2025).
Bommineni, V. L. et al. Performance of ChatGPT on the MCAT: the road to personalized and equitable premedical learning. Preprint at https://doi.org/10.1101/2023.03.05.23286533 (2023).
Jin, Q. et al. Hidden flaws behind expert-level accuracy of multimodal GPT-4 vision in medicine. Preprint at https://arxiv.org/abs/2401.08396 (2024).
Prokopenko, M. et al. Self-organizing hierarchies in sensor and communication networks. Artif. Life 11, 407–426 (2005).
MAFFRE et al. Messidor-2. ADCIS. https://www.adcis.net/en/third-party/messidor2/ (2025).
Niemeijer, M. et al. Retinopathy online challenge: automatic detection of microaneurysms in digital color fundus photographs. IEEE Trans. Med. Imaging 29, 185–195 (2010).
Decencière, E. et al. FEEDBACK ON A PUBLICLY DISTRIBUTED IMAGE DATABASE: THE MESSIDOR DATABASE. Image Anal. Stereo. 33, 231–234 (2014).
Abràmoff, M. D. et al. Automated analysis of retinal images for detection of referable diabetic retinopathy. JAMA Ophthalmol. 131, 351 (2013).
Abràmoff, M. D. et al. Considerations for addressing bias in artificial intelligence for health equity. Npj Digit. Med. 6, 1–7 (2023).
Krause, J. et al. Grader variability and the importance of reference standards for evaluating machine learning models for diabetic retinopathy. Ophthalmology 125, 1264–1272 (2018).
Saenz, A. D., Harned, Z., Banerjee, O., Abràmoff, M. D. & Rajpurkar, P. Autonomous AI systems in the face of liability, regulations and costs. Npj Digit. Med. 6, 185 (2023).
Brin, D. et al. Comparing ChatGPT and GPT-4 performance in USMLE soft skill assessments. Sci. Rep. 13, 16492 (2023).
Pugh, J. A. et al. Screening for diabetic retinopathy. The wide-angle retinal camera. Diabetes Care 16, 889–895 (1993).
Lin, D. Y., Blumenkranz, M. S., Brothers, R. J. & Grosvenor, D. M. The sensitivity and specificity of single-field nonmydriatic monochromatic digital fundus photography with remote image interpretation for diabetic retinopathy screening: a comparison with ophthalmoscopy and standardized mydriatic color photography. Am. J. Ophthalmol. 134, 204–213 (2002).
AMA. H-480.939 Augmented Intelligence in Health Care (AMA; 2025); https://policysearch.ama-assn.org/policyfinder/detail/augmented?uri=%2FAMADoc%2FHOD.xml-H-480.939.xml.
American Medical Association (AMA) Augmented Intelligence Development, Deployment, and Use in Health Care 2024. https://www.ama-assn.org/system/files/ama-ai-principles.pdf (2025).
FDA. Artificial Intelligence and Machine Learning (AI/ML)-Enabled Medical Devices (FDA, 2025); https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-and-machine-learning-aiml-enabled-medical-devices.
Abramoff, M. D. & Char, D. What do we do with physicians when autonomous AI-enabled workflow is better for patient outcomes? Am. J. Bioeth. https://www.tandfonline.com/doi/abs/10.1080/15265161.2024.2377111 (2025).
Photocoagulation for diabetic macular edema. Early treatment diabetic retinopathy study report number 1. Early treatment diabetic retinopathy study research group. Arch. Ophthalmol. 103,1796–1806 (1985).
Davis, M. D. et al. Risk factors for high-risk proliferative diabetic retinopathy and severe visual loss: early treatment diabetic retinopathy study report #18. Invest. Ophthalmol. Vis. Sci. 39, 233–52 (1998).
Wilkinson, C. P. et al. Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales. Ophthalmology 110, 1677–1682 (2003).
ISO 13485:2016. Medical devices – Quality management systems – Requirements for regulatory purposes. International Organization for Standardization. https://www.iso.org/standard/59752.html (accessed 2025).
Acknowledgements
The publicly available Messidor-2 dataset was kindly provided by the Messidor program partners (see https://www.adcis.net/en/third-party/messidor/).
Author information
Authors and Affiliations
Contributions
Conception or design of the work: M.S.H., T.D., and M.D.A. Data collection: M.S.H. Data analysis and interpretation: M.S.H. Drafting the article: M.S.H. and M.D.A. Critical revision of the article: T.D. and M.D.A. Supervision: M.D.A. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing interests
M.D.A. reports the following conflicts of interest: patents and patent applications assigned to the University of Iowa and Digital Diagnostics relevant to the subject; Director, Consultant, shareholder, Digital Diagnostics Inc; Executive Secretary, Healthcare AI Coalition, Washington DC; Treasurer, Collaborative Community on Ophthalmic Imaging, Washington DC; member, American Academy of Ophthalmology (AAO) AI Committee; member, AI Workgroup Digital Medicine Payment Advisory Group (DMPAG) of the American Medical Association. T.D. declares no competing financial interests and a nonfinancial interest as a member of multiple study teams using LumineticsCore from Digital Diagnostics and as co-lead of Johns Hopkins University’s Bloomberg Distinguished Professorship Cluster on Global Advances in Medical Artificial Intelligence. T.D. is an Editor for npj Digital Medicine and played no role in the internal review or decision to publish this article. M.S.H. reports no financial or non-financial competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Hunt, M.S., Dai, T. & Abràmoff, M.D. Evaluating commercial multimodal AI for diabetic eye screening and implications for an alternative regulatory pathway. npj Digit. Med. 9, 42 (2026). https://doi.org/10.1038/s41746-025-02216-7
Received:
Accepted:
Published:
Version of record:
DOI: https://doi.org/10.1038/s41746-025-02216-7