Table 7 Sensitivity analysis for the detection loss weight (λdet)

From: GLANCE: continuous global-local exchange with consensus fusion for robust nodule segmentation

λdet

Seg. dice (%)

Det. sens @ 1 FP/s (%)

Det. CPM (avg. sens)

0.2

96.1

94.8

91.7

0.3 (Ours)

96.4

95.7

92.1

0.4

96.0

95.3

91.9

0.5

95.7

94.6

91.3

  1. Performance is measured by segmentation dice and detection sensitivity @ 1 FP/s and CPM.