Table 1 Cryo-EM data collection, refinement and validation statistics

From: Structural mechanisms of potent lysophosphatidic acid receptor 1 activation by nonlipid basic agonists

Data collection

CpY-LPA1-Gi-scfv16

Microscope

Titan Krios (Thermo Fisher Scientific)

Voltage (keV)

300

Electron exposure (e−/Å2)

50.362

48.405

Detector

Gatan K3 summit camera (Gatan)

Magnification

×105,000

Defocus range (μm)

−0.8–1.6

−0.6–1.6

Pixel size (Ã…/pix)

0.83

Number of movies

5013

3312

Symmetry

C1

Picked particles

3,667,591

2,393,563

Final particles

277,598

Map resolution (Ã…)

2.86

FSC threshold

0.143

Model refinement

Atoms

8,779

R.m.s. deviations for ideal

Bond lengths (Ã…)

0.004

Bond angles (°)

0.553

Validation

Clashscore

8.03

Rotamers (%)

0.11

CCmask

0.69

EMRinger score

2.32

Ramachandran plot

Favored (%)

96.96

Allowed (%)

3.04

Outlier (%)

0