Table 3 Comparison of Bimodal fitting parameters for VincTS and VincTS + mScarlet-RIAM using the Cascade FRET energy transfer model
Lifetime and force bimodal fit parameters for VincTS only | Lifetime and force bimodal fit parameters for VincTS + mScar-RIAM | ||||
|---|---|---|---|---|---|
Lifetime Bimodal Fit Parameters: | Lifetime Bimodal Fit Parameters: | ||||
Lifetime (ns) | Std. dev. | Lifetime (ns) | Std. dev. | ||
x1 | 1.893 | 0.039 | x1 | 2.154 | 0.182 |
σ1 | 0.249 | 0.026 | σ1 | 0.437 | 0.121 |
A1 | 0.838 | 0.080 | A1 | 0.584 | 0.993 |
x2 | 2.547 | 0.072 | x2 | 3.146 | 0.270 |
σ2 | 0.305 | 0.051 | σ2 | 0.406 | 0.181 |
A2 | 0.571 | 0.048 | A2 | 0.362 | 0.118 |
Forces Bimodal Fit Parameters: | Forces Bimodal Fit Parameters: | ||||
|---|---|---|---|---|---|
Force (pN) | Std. dev. | Force (pN) | Std. dev. | ||
x1 | 2.737 | 0.080 | x1 | 3.067 | 0.0583 |
σ1 | 0.413 | 0.046 | σ1 | 0.409 | 0.0394 |
A1 | 0.678 | 0.065 | A1 | 0.784 | 0.0666 |
x2 | 3.172 | 0.019 | x2 | 3.454 | 0.0219 |
σ2 | 0.161 | 0.030 | σ2 | 0.114 | 0.0292 |
A2 | 0.686 | 0.140 | A2 | 0.633 | 0.1345 |