Fig. 2: MAIA microperimetry 0% fixation loss exam, best-corrected distance visual acuity (BCDVA) and Amsler grid at each time period of eye 2OS.

A Before MLR, MAIA showing the retinal sensitivity map, <0dB sensitivity at all points on the 10° grid, 100% reduced thresholds and average threshold of 0dB, and the Amsler grid demonstrating a large positive scotoma (lower right); B At 6 months after treatment, MAIA showing the retinal sensitivity map, all sensitivities on the 10° grid, 100% reduced thresholds and average threshold of 0.1dB, and the normal Amsler grid (lower right); C At 12 months after treatment, MAIA showing the retinal sensitivity map, all sensitivities on the 10° grid, 100% reduced thresholds and average threshold of 1.6dB, and the normal Amsler grid (lower right); D At 18 months after treatment, MAIA showing the retinal sensitivity map, all sensitivities on the 10° grid, 97.3% reduced thresholds and average threshold of 10.0dB, and the normal Amsler grid (lower right).