Introduction

Magnetic resonance imaging (MRI) is a widely adopted noninvasive diagnostic modality for visualizing internal body structures and monitoring physiological and pathophysiological conditions. Owing to the high hydrogen content in living organisms, particulary in water and organic molecules, proton magnetic resonance imaging (1H-MRI) emerges as the predominant MRI technique in clinical applications. The nearly 100% natural abundance of the 1H isotope and its advantageous intrinsic properties, such as a spin of ½ and a gyromagnetic ratio (γ) of 42.6 MHz T−1, render it easily detectable at the relatively low magnetic fields employed in clinical scanners (1.5 T). Although 1H-MR imaging is commonplace, the administration of contrast agents can enhance differentiation between healthy tissues and pathologies. However, clinically approved contrast agents containing gadolinium raise concerns due to potential toxicity, accumulation1, and limited ability to provide additional information on tissue pathology. Consequently, there is a growing imperative to develop gadolinium-free contrast agents or probes to enhance the safety of MR imaging and the precision of pathology detection. 1H-MRI provides valuable insights into the morphology and composition of tissues in the body. Nevertheless, to garner complementary information on tissue function, metabolism, and physiology beyond the capabilities of traditional proton MRI, specialized MR techniques utilizing isotopes other than hydrogen, X-nuclei MRI, are currently under development. Among the various nuclei applicable in X-nuclei MRI – such as 13C, 17O, 23Na, 19F, and 31P – techniques for imaging phosphorus and fluorine have attracted considerable interest in recent years2,3,4,5,6,7,8,9,10,11,12,13,14. One of the promising X-nuclei, phosphorus, is characterized by the stable natural monoisotope 31P possessing a nonzero magnetic moment with a spin value of ½ and a γ of 17.2 MHz T−1. Notably, the magnetic sensitivity of 31P is 60% lower than that of 1H. Despite phosphorus being roughly 10 times less abundant in the human body mass and having ~2.5 times less magnetic momentum than hydrogen protons, sensitive radiofrequency coils enable the detection of phosphorus even at the low magnetic fields typically used in clinical settings. Historically, 31P-MR has primarily been used to assess cell membrane composition, phosphorylated metabolite levels, the bioenergetic status of organs and tissues, and intracellular pH levels15,16,17,18,19,20,21,22. In recent years, its broader potential has been explored using responsive phosphorus and iron-based probes4,5, but its tendency to significantly overlap with physiological background signals within the MR frequency range remains a challenge. The solution to these problems could be a probe with a different chemical shift in phosphorus MR, as proposed in our previous publication6, where the in vivo use requiring specific exogenous probes for accurate measurement was discussed.

Another X-nucleus frequently investigated for clinical MRI applications is fluorine-19 (19F-MRI). This monoisotope possesses not only a negligible physiological concentration but also a high gyromagnetic ratio (40.1 MHz T−1), with MR specificity and sensitivity comparable to hydrogen (83% of 1H)23. Therefore, overlaying the 19F-MR signal from exogenous probes onto the anatomical background obtained by 1H-MRI measurements facilitates monitoring the biodistribution and pharmacokinetics of probes within the body. The fluorine-based probes are widely examined in the preclinical studies2,3,7,8,9,10,11,12,13 and first trials of clinically usable probes were published14. Importantly, 19F-MR can be performed using common scanners and radiofrequency coils, requiring only minor hardware adjustments. However, compounds containing fluorine are often hydrophobic and poorly soluble in water, limiting their clinical utility to a significant extent.

Previous X-nuclei research, including work from our group and others2,3,4,5,6,7,8,9,10,11,12,13,14,24,25, has demonstrated that hydrophilic biocompatible phospho- and fluoro-based MR probes serve as suitable probes for MR imaging and spectroscopy (MRS). In comparison to low molecular weight probes, these macromolecular compounds exhibit enhanced solubility, a higher P/F atoms content, and prolonged biological half-life. Moreover, their structures, compositions and dimensional characteristics can be specifically tuned, allowing for elimination from the organism after measurements. They are also easily modifiable for use as drug carriers26,27. Due to their greater hydrodynamic size, they can passively accumulate in specific pathologies, such as tumors through the enhanced permeability and retention (EPR) effect28 or inflammation via extravasation through leaky vasculature and subsequent inflammatory cell-mediated sequestration29. This accumulation can be exploited for targeted imaging of these pathologies.

Fluoropolymers offer the advantage of being bioinert and easily distinguishable, providing a 19F-MR signal without the biological background. However, they are not without limitations. Frequently hydrophobic, their solubility tends to decrease with increasing fluorine content. In contrast, certain phoshpopolymers can be design to be highly soluble in aqueous solutions, even with a high phosphorus content, and are biocompatible, and, in some cases, biodegradable. Nonetheless, commonly used phosphopolymers like as poly(2-methacryloyloxyethyl phosphorylcholine) (pMPC), poly(phosphoesters), or some poly(phosphazenes) often exhibit a chemical shift similar to naturally occurring biomolecules, making their 31P-MR signal challenging to distinguish from the signal of surrounding tissues30,31. Signal recognition of certain phosphopolymers can be enhanced, as demonstrated in our prior research6, where we utilized a unique phosphopolymer in which one of the oxygen atoms in the phosphoester groups (P = O) was replaced with sulfur to form a thiophosphoester groups (P = S)—changing the chemical shift in phosphorus MR.

While various fluoropolymers or phosphopolymers for in vivo MR use have been described in recent literature, a significant scientific challenge remains in the development of probes capable of detecting changes in pathophysiological processes associated with the onset of specific disorders. One indicator of physiological abnormalities is the tissue-specific level of reactive oxygen species (ROS). ROS encompass a group of naturally occurring, chemically reactive compounds containing oxygen, including the superoxide anion radical, hydroxyl radical, hydroperoxyl radical, singlet oxygen, and various nitrogen and hypochlorite radicals, all more reactive than ground-state oxygen32. Typically generated through the partial reduction of molecular oxygen via both endogenous (physiological) and exogenous (environmental) oxidative processes within biological systems33, ROS are produced in many cellular compartments, with mitochondria being a major source. At moderate levels, ROS are required for several cellular functions, including gene expression34, and are involved in diverse biological processes such as host defense, signaling, tissue development, injury response, as well as hypertension and tumor development35,36,37,38. Inflammation sites and tumors are generally characterized by a significant increase in ROS concentration39, commonly formed by both the immune system and cancer cells to create a microenvironment unique among healthy tissues. Importantly, changes in ROS levels are also associated with chemotherapy and radiotherapy39,40,41.

The standard methods for ROS-detection in vitro are based on the fluorescence, which is highly sensitive, but not clinically relevant. In diagnostics there are several advanced techniques for detecting ROS, such as positron emission tomography (PET), ultraweak photon emission imaging (UPE), and optical and photoacoustic imaging, have been integrated into experimental medical applications40,41,42,43,44,45,46. However, these methods face limitations that hinder their application in clinical practice. PET exposes the patients to ionizing radiation, UPE is restricted to superficial areas, and optical imaging encounters challenges with poor tissue penetration47. Encouragingly, X-nuclei MRI holds promise in this realm, but its use is contingent upon the development of suitable probes. As cancer-specific factors are generally lacking in CAs MRI methodology, no ROS-detecting method is currently available in MR. To address those limitations, we designed a water-soluble polymer probe with high phosphorus and fluorine content and specific responsivity. Hypoxia, measured using MR methods, is tightly connected with oxidative stress and ROS-targeting therapies used in radiotherapy usually encounter the problem of ROS generation overwhelming the antioxidant mechanisms of the cell, leading to oxidative stress. Thus, ROS can play both pro- and anti-tumor role in a context-dependent manner and its sensitive detection would be highly beneficial.

The primary aim of this investigation is to introduce an innovative method utilizing dual 31P/19F-MR for in vivo localization and assessment of tumor tissue employing hydrophilic phospho-/fluoropolymer responsive to ROS changes. Initially, ROS production was evaluated in vitro using a highly sensitive fluorogenic reagent to detect extracellularly released oxidation products. Subsequently, we monitored their impact on the chemical shift of the polymer probe under various oxidative conditions using 31P-MRS across various cell lines, validating its performance in vivo using an murine tumor model. Despite the ability of modern methods to detect ROS changes, quantifying alterations in their concentrations remains a challenge.

A crucial aspect of our analysis involved assessing the performance of our biocompatible, ROS-responsive polymer probe under conditions closely resembling clinical magnetic field strengths, specifically 4.7 T. Demonstrating high specificity and responsiveness, the probe showed its capacity to detect pathophysiological conditions characterized by the presence of ROS. While 31P-MRS was used to detect ROS produced in a tumor environment, fluorine MR spectroscopy and imaging were employed to monitor changes in the biodistribution of the probe over time. As an in situ reference, fluorine adeptly localized the probe precisely in instances where the phosphorus signal disappeared due to shifting caused by ROS-induced oxidation. We anticipate that the dual MR probe presented in this study will offer new insights into the detection, diagnosis and subsequent treatment of tumors and inflammatory diseases.

Results

Synthesis of the polymer probes

To track in vivo biodistribution of the exogenously administered probe simultaneously with tissue-specific ROS production using 31P/19F-MR, the structure of the probe was modified to provide a sufficiently high and sustained signal-to-noise ratio (SNR) that would be easily distinguishable from the signals generated by the naturally occurring biomolecules. The probe also needed to be sufficiently responsive and sensitive to change its chemical composition in the presence of ROS. For these purposes, we developed custom biocompatible polymer probes containing thiophosphoester (referred to as P = S for simplicity) and/or trifluoromethyl (CF3) groups. While the P = S groups served as an ROS scavenger detectable by 31P-MR, the CF3 groups enabled the probe to be precisely localized using 19F-MR. Specifically, the reversible addition–fragmentation chain transfer (RAFT) polymerization technique in the presence of dithiobenzoate-based chain transfer agent and azoinitiator was used to produce a water-soluble O-(2-(methacryloyloxy)ethyl) O-(2-(trimethylamoniumyl)ethyl) phosphorothioate (TMPC)-based homopolymer of zwitterionic character (31P-polymer) and a statistical copolymer of TMPC with a methacrylamide comonomer bearing the bis(trifluoromethyl)benzylamine group (Ma-βAla-BTFBA), referred to as the 31P/19F-polymer (for structures, see Scheme 1; the reaction scheme is presented in Supplementary Fig. 1). While the 31P-polymer was prepared by direct polymerization of the TMPC monomer, the 31P/19F-polymer copolymer was obtained by a post-polymerization aminolytic reaction of the TT-activated precursor p(TMPC-co-Ma-βAla-TT) with BTFBA. The molecular weights were 22.1 kg·mol−1 for the 31P-polymer and 16.7 kg·mol−1 for the 31P/19F-polymer. Both (co)polymers were characterized by low dispersity (Ð ≤ 1.1).

Scheme 1
scheme 1

Visual representation of the in vitro and in vivo application of the polymers.

Chemical structures of the phosphopolymer (31P-polymer) and phospho-/fluoropolymer (31P/19F-polymer) with assigned experimental use in the study.

ROS production under hypoxic conditions

ROS production was confirmed by fluorescence measurements of murine mammary carcinoma 4T1 cell line, derived from mouse breast cancer, where the conversion of OxyBURST Green H2HFF BSA (OB) dye to its fluorescent derivative was observed. Notably, the 4T1 cell line exhibited a higher total fluorescence emission ratio compared to the medium with OB alone and OB with different concentrations of hydrogen peroxide H2O2 (up to 210 min for 50 nM and up to 40 min for 100 nM) (Fig. 1). In the control samples, the highest signal increase over time was observed in the OB samples treated with 100 nM H2O2. The mentioned OB relevance using extracellular, rather than intracellular ROS production, was confirmed through complementary experiments. Specifically, the internalization process in PANC-1 (evaluated via confocal microscopy; Dy647 dye) and RAW264.7 macrophages (assessed using 19F-MRS on 14 T MR) demonstrated decreased efficacy when employing the dual 31P/19F-polymer as opposed to utilizing the 31P-polymer alone and no fluorine signal from cells treated with the polymer overnight. The results are presented in Supplementary Fig. 2.

Fig. 1: Results of in vitro experiments.
figure 1

a Fluorescence measurement of ROS production in 4T1 cells using the nonfluorescent dye OxyBURST Green H2HFF BSA (OB), which is oxidized by ROS to the fluorescently active derivative. Results are presented as the total emission (photons∙s−1) in controls, normalized to the signal of 4T1 cells in a medium with 10 mg∙mL−1 OB over time. b 31P/19F -polymer in phantom (cp = 100 mM; V = 100 µL) measured using 19F- and 31P-MRS and 1H/19F/31P-MRI. 19F- (red) and 31P-(green) MRI data are overlaid with 1H-MRI signal. c Relative 31P-MRS amplitude decreases (%) in different ROS-triggered oxidative conditions: 31P-polymer with (left) H2O2 and (right) 4T1 cells, reflecting the oxidation of the P = S (∆δ ~ 60 ppm) signal to the P = O (∆δ ~ 0 ppm) signal over time.

31P-polymer MR signal changes under hypoxic conditions

The 31P-MRS signal originating from the P = S groups within the phosphorus-based 31P-polymer structure remained detectable across all tested conditions, including the short-time measurements. However, the reduction in signal amplitude varied among experiments (Fig. 1 and Supplementary Fig. 3). Consistent with previously 31P-NMR findings, the first two highly oxidizing model conditions, involving aqueous solutions of H2O2 and sodium hypochlorite NaClO, similarly triggered a reduction in the signal6. In the presence of H2O2, the polymer underwent oxidation, leading to a 47% conversion of the signal from the P = S groups (∆δ ~ 60 ppm) to the P = O groups (∆δ ~ 0.0 ppm) within the first hour. Maximum oxidation of 68 % was reached after 24 h. Incubation of the probe in NaClO solution resulted in rapid and significant oxidation, evidenced by a remarkable 97% decrease in the P = S signal within one hour. Additionally, variations in ROS-triggered oxidation were noted among cell cultures: human leukemia monocytic THP-1 cells exhibited amplitude decreases of 14% (within the first 12 h) and 20% (at 24 h from onset), human prostate adenocarcinoma PC3 cells showed reductions of 13% and 19%, and 4T1 cells influenced P = S signal by 8% and 17%, respectively. No significant changes in signal shift or amplitude (0.33 ± 1.85%) were observed in the 31P-MR spectra obtained from the polymer in the medium, even over an extended data collection period of 18 h. The viability of a series of PC3 cells stored in Eppendorf tubes at room temperature, similar to the conditions used for MR measurements, remained within a range of 90–93% at all time points (1–3 h) (data not shown).

The 31P/19F-polymer was measured using 31P- and 19F-MR spectroscopy and magnetic resonance spectroscopic imaging (MRS/MRSI) to determine signal sensitivity (Supplementary Fig. 4) and changes in the ROS-triggered signals. MRS data indicated frequency shifts in the signals suitable for further in vivo experiments, with high signal sensitivity achieved even over short measurement periods (scan time ST = 3 min). MRSI generated signals for both phosphorus (ST = 10 min) and fluorine (ST = 3 min). Under oxidative conditions, the phosphorus P = S signal decreased in accordance with the behavior of the 31P-polymer. In contrast, the fluorine signal remained stable, confirming the stability of the polymer (Supplementary Fig. 5).

These results were successfully repeated on the clinical 3 T and preclinical 7 T MR scanner, where the 31P-polymer with H2O2 underwent full oxidation after 24-h incubation (Supplementary Figs. 6, 7a, c).

In vivo MR of polymer biodistribution and oxidation-triggered signal changes

The high phosphorus content in the polymer provided a substantial MR signal, as evidenced by the high chemical shift of the P = S groups in 31P-MR (∆δ ~ 60 ppm) at low, nontoxic concentrations (Fig. 2a). This characteristic made the MR signal easily distinguishable from the biological background signals in vivo (~0 ppm). The quantified phosphorus MR signal originating from the P = S groups of the 31P/19F-polymer exhibited the same chemical shift as the previously tested 31P-polymer containing TMPC monomer units only. Additionally, the fluorine signal displayed a shift in 19F-MRS (∆δ ~ 20 ppm) compared to the anesthesia signal (Fig. 2b), resulting in a 100% specificity. This shift serves as a crucial factor in enhancing the precision and accuracy of our in vivo imaging technique, as it guarantees a clear differentiation between the fluorine signal from the polymer and the background signal originating from the anesthesia.

Fig. 2: Results of in vivo experiments.
figure 2

a Experimental schematic outlining the steps including tumor induction, injection of 31P/19F-polymer, and MR measurement setup. b MR chemical shift between the 31P/19F-polymer and anesthesia (isoflurane; ∆δ ~ 20 ppm, 19F-MRS), and between physiological signal (metabolites; ∆δ ~ 60 ppm, 31P-MRS). c Results of proof-of-principle in vivo 19F-MRI after retro-orbital 31P/19F-polymer injection. Overlaid 1H/19F-MRI with the fluorine signal highlighted in red. Results are visible 6 h (Day 0 + 6 h), 24 h (Day 1), and 48 h (Day 2) post-injection. d Results of in vivo 31P-MRS and 19F-MRS/MRI in response to ROS-triggered changes after I.T. 31P/19F-polymer injection. Overlaid 1H/19F-MRI and 19F-MRS with fluorine signal presented in red, and 31P-MRS data with the phosphorus signal highlighted in green; both measured 6- and 24-h post-injection (Day 0 + 6 h and Day 1). On the right, average SNR values of the 31P/19F-polymer injected I.T. for both 19F- and 31P-MRS; * indicates 31P-MRS SNR values below the detection limit (<1); both measured 0.5–48 h post-injection (Day 0 to Day 2).

Initial in vivo measurements of polymer biodistribution revealed significant accumulation of the polymer in the bladder, tumor (following intravenous I.V. injections via the lateral tail vein or retro-orbitally via the venous sinus R.O.), and kidneys (following I.V. injection via the lateral tail). The intravenous injection resulted in the highest 19F-MR signal two days after polymer administration (Supplementary Fig. 7). No immediate signal was observed after the injection, with only a weak fluorine MRS signal detected on day one. Conversely, retro-orbital administration initially resulted in visible 19F-MR signal solely in the bladder, with accumulation in tumor tissue observed one day after administration. The rest of the polymer was excreted in urine, evident from a strong signal in the bladder at all measurement points. No signal from the tumor was detected on the second day post-administration (Fig. 2c).

In subsequent in vivo analysis, mice underwent 31P-MRS and 19F-MRS/MRI at three-time points: immediately after the 31P/19F-polymer intratumoral (I.T.) injection, and then 24 and 48 h after administration (Fig. 2d). The 31P-MRS signal of the polymer was detected immediately after injection in four out of five animals (SNR = 2.20 ± 0.65). On day one (24 h PI), a decrease in the phosphorus MRS signal was observed, indicating the conversion of the phosphorus signal from P = S to P = O due to ROS production in hypoxic cancer tissue. The SNR of the integral at this point (0.84 ± 0.03) was considered noise. Conversely, the 19F-MRS signal was detected immediately after injection in all measured animals (SNR = 3.19 ± 0.95) persisting at 24 h (SNR = 1.38 ± 0.17) and 48 h (1.14 ± 0.16). These findings indicate that the polymer was not completely eliminated from the body until that time point. Additionally, the 1H/19F-MR image overlay obtained 24 h post-injection (PI) clearly indicates that the fluorine signal originated from tumor tissue (Fig. 2a). Throughout the experiment, the fluorine signal remained higher than the phosphorus signal. Changes in 19F- and 31P-MRS SNR over time are depicted in Fig. 2b. A summary of the independent measurements, along with additional details and data, is provided in Supplementary Fig. 8. In summary, our results underscore the sufficient signal detection and localization of the 31P/19F-polymer using 31P- and 19F-MR techniques in vivo, even 48 h PI, highlighting the ROS-responsiveness of the dual polymer in the cancer tissue.

Discussion

In response to the gap in preclinical biocompatible and specific probes for X-nuclei MR in pathology, we investigated the MR properties of ROS-sensitive phospho-/fluoropolymers. Initially, in vitro experiments were conducted to establish baseline ROS production in cell cultures using fluorescent probes. Detecting ROS is challenging due to their low concentrations (often within the nanomolar range), short half-lives, and the impact of surrounding oxygen levels, which can trigger oxidative stress and structural changes48. Even atmospheric oxygen levels of 21% alone are capable of inducing oxidative stress without additional stimulation. However, physiological oxygen concentrations in the human body are much lower49. Therefore, it is feasible to measure ROS at lower oxygen concentrations. Signal fluctuations led to comparing several controls to accurately reflect probe oxidation. Future ROS measurements may benefit from atmospheric control units or bioreactors implementation.

ROS measurement in cell cultures is influenced by factors like spontaneous and H2O2-induced apoptosis, which vary with cell density33. Some researchers report on a linear increase in the rate of HO· production with rising cell density and normalize ROS levels to the number of viable cells50, which could be tested in future ROS-production experiments, where additional information can be gained from varying cell densities. Additionally, nonadherent cell lines in suspension allow immediate probe application, whereas adherent cultures require an incubation time ranging from a few hours up to one day33. This factor was reflected in THP-1 cell line behavior, where cells enclosed in Eppendorf tubes with growth medium more closely resembled physiological conditions.

A comparison of ROS regulation in cancer vs. healthy cell lines was discussed in ref. 34, where it showed that cancer cells, whose antioxidant systems are already triggered, are more sensitive to ROS increases and are unable to achieve redox balance, leading to higher cancer cell death rates. Dead cells can also contribute to hypoxia, affecting the oxidation rate of P = S groups in the polymer probe. Furthermore, the increase in the phosphorus signal observed during our initial measurements may have reflected changes in MR properties, like relaxation times.

In prostate cancer cells (PC3, DU145, LNCaP) ROS generation is higher than in normal cells51. In our study, PC3 cells were used for in vitro MR of the responsive polymer, with H2O2 and NaClO as controls for hypoxic and inflammatory environments. As previously demonstrated, PC3 plays an essential role in ROS production through activation of NADPH oxidase (NOX), an extramitochondrial source involved in tumor progression and metastasis that can lead to ROS increase in the tumor microenvironment38. Elevated oxidative signaling in various type of cancers, including breast, pancreas, bladder, colon, lung, and prostate cancer, promotes tumor progression52. Furthermore, untreated tumors typically have very low oxygen levels, comparing to median oxygenation typically ranges between 3 and 7.4%, and exhibits oxygen levels between 0.3 and 4.2%, affecting ROS and polymer oxidation rates.

For ROS fluorescent detection, simple buffers, such as phosphate-buffered saline (PBS), Hanks’ balanced salt solution (HBSS), or 4-(2-hydroxyethyl)−1-piperazineethanesulfonic acid (HEPES) are preferable over complex media. Additionally, a minimal loading dose is recommended to obtain a stronger fluorescence signal33. We used FluoroBrite DMEM, a specialized medium for extended optical measurements, to minimize the high impact of PBS on cell viability and without the addition of serum or phenol red achieve low background fluorescence36.

Strict adherence to physiological conditions is crucial for cell viability in prolonged experiments. In this study, cell viability was assessed in Eppendorf tubes at room temperature, and remained high (>90%). In vitro 31P-MR spectroscopy showed signal decay observed in normal cell lines, which may be attributed to the decline in culture viability over time, unlike resistant cancer cell lines. This phenomenon was evident even in prolonged measurements (>24 h), where the decline in the P = S signal was observed across all cell cultures.

Under model oxidative conditions with H2O2 or NaClO, the P = S phosphorus signal decreased rapidly due to high oxidation, contrasting with cell lines behavior. Quantification methods for MR signals were adapted for polymer structure changes, with P = S signals shifting to P = O, overlapping with physiological phosphorus signals53,54. Therefore, changes in signal amplitude under oxidizing conditions were quantified based on the P = S signal. Another reason for adopting this approach is the potential for the physiological P = O phosphorus signal to increase over time; spectral changes in adenosine triphosphate levels, for example, are associated with cell death43. In the case of the 31P/19F-polymer, fluorine signal remained unchanged under the influence of ROS over time, confirming polymer tracking using fluorine MRI and MRSI.

In vivo experiments used a copolymer comprising fluorine and phosphorus groups for dual 31P/19F-MR, allowing ROS triggered functionality assessment and provided an on-site reference for localization in the body. The exogenous probe precise localization and functionality, even at low concentrations in vivo, offers new opportunities for preclinical and clinical applications, such as is in theranostics, where phosphopolymers are covalently bound to antitumor drugs like 5-fluorouracil (5-FU), where therapeutic effects, biodistribution, and pharmacokinetics of the drug are simultaneously monitored using 31P/19F-MR in vivo (data not published). However, differences in 31P-MRS amplitude of the physiological signal due to factors like hypoxia in the tumor and the loss of cells over time55. Therefore, signals within this frequency range can be challenging to quantify.

With these considerations in mind, we aim to obtain information from fluorine MR. The polymer’s molecular weight (~17 kDa) facilitated tumor accumulation via the EPR effect, enhancing pharmacokinetics and ensuring excretion from the body post-task (the renal threshold for methacrylate-based polymers is ~45 kDa56). Biodistribution analysis confirmed that the length of the polymer chains enabled it to function effectively as a passive tumor-specific probe, remaining MR-detectable for up to two days. The increase in the signal observed after the retro-orbital injection is particularly encouraging, as it allows higher dosages and easier handling, deemed less stressful and more humane for the animals involved57. The higher signals observed after the I.T. injection are connected with the injection method, as both intravenous and intratumoral injections were measured at the same post-injection time points. Intravenous injections require more time for the polymer to passively accumulate and exhibit higher polymer dissolution within the system. Poor perfusion and elimination rates (after 24 h) can provide valuable insight for our future measurements, particularly as we aim to observe signal changes across various models and track the impact of attached drugs or ROS-based treatments on tumor size over time. Prolonged retention of the probe within the tumor allows for extended treatment duration and its biocompatibility ensures the safety of this system even during prolonged treatments. The I.T. injections in the long-term preclinical studies can serve as an indicator of the possible pathology onset with preferably I.V. injections used in the future and higher dosages.

The fluorine signal originating from the bladder and kidneys indicated polymer elimination from the body by day two post-injection. High 19F-MRS signal amplitude observed 6 h PI in animals that received the retro-orbital injection indicates that the signal did not solely originate from the bladder (as visible in the MRI) but may have also originate from the tumor, where the signal is strongly suppressed. Six hour after intravenous injection, the MR signal was low and only slightly detectable in the kidney, indicating that the polymer had yet to accumulate in the tumor. An increase in the signal in both MRS and MRSI was detected only 48 h PI.

Our ongoing experimental work highlights the rapid polymer probe accumulation in tumors and high responsiveness. Pending confirmation of ROS-triggered signal changes in vivo, we expect to further test the dual 31P/19F-MR probe as an indicator of ROS levels in bacterial infections and cancer using different preclinical animal models and ultrahigh field MR. This probe could also be valuable for quantification ROS-based therapies in cancer treatment. The growing body of experimental data underscore the covert role of ROS generation in eliminating cancer cells via different metabolic pathways34. The ability of P = S groups to scavenge free radicals and their oxidation to form P = O groups58,59,60,61 may have therapeutic effects on cancer and inflammation. In parallel, saturation of P = S groups of the polymer with free radicals over time can be detected using 31P-MR. This property allows real-time in vivo imaging of the redox environment across clinically relevant imaging methods, demonstrating its utility in noninvasive imaging of ROS-rich pathologies, particularly in capturing the physiological and anatomical aspects of these conditions.

Methods

Chemicals

The compounds 2,2′-azobis(2-methylpropionitrile) (AIBN), 2-cyano-2-propyl benzodithioate (CPB), ethylene glycol, 4-methoxyphenol (MEHQ), thiophosphorylchloride, N,N’-dicyclohexylcarbodiimide (DCC), triethylamine (Et3N), and 2-thiazoline-2-thiol (TT) were purchased from Sigma-Aldrich, Czech Republic. The chemicals 3-aminopropanoic acid, 3,5-bis(trifluoromethyl)benzylamine (BTFBA), 2-hydroxyethyl methacrylate (HEMA), methacryloyl chloride, and trimethylamine (Me3N) were purchased from TCI Europe, Belgium. All solvents (HPLC grade), obtained from VWR International, Czech Republic, were dried over a layer of activated molecular sieves (4 Å) before use.

Synthesis of monomers

Synthesis of TMPC was performed according to a previously described procedure by reacting thiophosphorylchloride with ethylene glycol to give 2-chloro-1,3,2-dioxaphospholane-2-thione, which further reacted with HEMA in the presence of Et3N to form 2-((2-thioxo-1,3,2-dioxaphospholan-2-yl)oxy)ethyl methylmethacrylate. The resulting TMPC monomer was obtained by subsequently opening the phospholane ring of 2-((2-thioxo-1,3,2-dioxaphospholan-2-yl)oxy)ethyl methylmethacrylate with Me3N6. Synthesis of 3-(3-methacrylamidopropanoyl)thiazolidine-2-thione (Ma-βAla-TT) was performed by acylating 3-aminopropanoic acid with methacryloyl chloride in an aqueous alkaline medium followed by the reaction of the formed 3-methacrylamidopropanoic acid with TT in the presence of DCC and DMAP, as described previously62.

Synthesis of polymers

The polymer known as p(TMPC), hereafter referred to as the 31P-polymer, was generated by RAFT polymerization of TMPC in the presence of CPB and AIBN in methanol at 60 °C for 16 h, as previously described6. The number-average molecular weight (Mn) and dispersity (Ð) of the polymer were 22.1 kg·mol−1 and 1.02, respectively. The polymer known as p(TMPC-co-Ma-βAla-BTFBA), hereafter referred to as the 31P/19F-polymer, was synthesized in three steps.

First, TMPC (2.0 g, 6.4 mmol) was dissolved in methanol (6 mL) and added to a mixture of CPB (37.5 mg, 0.17 mmol), AIBN (13.9 mg, 84.7 μmol), and Ma-βAla-TT (711.8 mg, 2.8 mmol) in dimethyl sulfoxide (4.2 mL). The polymerization mixture was thoroughly bubbled with argon and polymerized in a sealed glass ampoule at 70 °C for 16 h. After cooling to room temperature, the reaction mixture was precipitated into a 20-fold excess of acetone–diethyl ether (3:1) and reprecipitated from methanol into acetone. Centrifugation and vacuum drying of the precipitate afforded 1.23 g of the p(TMPC-co-Ma-βAla-TT)-DTB polymer precursor as an orange powder.

Second, a mixture of p(TMPC-co-Ma-βAla-TT)-DTB (350 mg, 28.2 μmol DTB groups) and AIBN (92.7 mg, 0.56 mmol) was dissolved in methanol (1.0 mL), thoroughly bubbled with argon, and incubated at 80 °C for 2 h. After cooling to room temperature, the reaction mixture was precipitated into a 20-fold excess of acetone–diethyl ether (3:1) and reprecipitated from methanol into acetone. Centrifugation and vacuum drying of the precipitate afforded 321 mg of the p(TMPC-co-Ma-βAla-TT) polymer precursor as a white powder. The Mn and Ð of the polymer were 12.4 kg·mol−1 and 1.1, respectively. The molar content of the TT groups was 16 mol%.

Third, BTFBA (37.4 mg, 0.15 mmol) was dissolved in dimethyl sulfoxide (0.6 mL) and added to a solution of p(TMPC-co-Ma-βAla-TT) (291 mg, 0.15 mmol) in methanol (2.2 mL). The reaction mixture was incubated at room temperature overnight. After precipitation into a 20-fold excess of acetone–diethyl ether (3:1), the precipitate was dissolved in methanol and purified by gel filtration using a Sephadex LH-20 cartridge in methanol with 10 mM LiBr. The polymer was isolated by precipitation into acetone followed by centrifugation and vacuum drying to give 220 mg of p(TMPC-co-Ma-βAla-BTFBA) as a white powder. The Mn and Ð of the polymer were 16.7 kg·mol−1 and 1.1, respectively. The molar content of the BTFBA groups was 15 mol%.

UV–visible spectrophotometry

Spectrophotometric analysis of the polymers was carried out in quartz glass cuvettes on a Specord Plus UV–vis spectrophotometer (Analytik Jena, Germany). The molar content of the terminal DTB groups and pendant TT groups in the polymers was determined in 1 cm quartz glass cuvettes at 302 nm and 305 nm at concentrations of 1.0 and 0.1 mg·mL−1 in methanol using a molar absorption coefficient of 12,100 and 10,300 L·mol−1·cm−1, respectively.

High-performance liquid chromatography

The purity of all low-molecular-weight compounds synthesized in this study was verified using a high-performance liquid chromatography (HPLC) system (Shimadzu, Japan) equipped with an internal UV–Vis diode array detector (SPD-M20A). Separation was performed using the Chromolith HighResolution RP18 endcapped reversed-phase column (Merck, USA) with a linear gradient (0–100%) of a water–acetonitrile mixture containing 0.1% TFA at a flow rate of 2.5 mL·min−1.

Size exclusion chromatography

The number-average molecular weight, weight-average molecular weight (Mn and Mw), and dispersities (ÐSEC, ÐSEC = Mw/Mn) of TMPC-based polymers were determined by size exclusion chromatography using a HPLC system (Shimadzu, Japan) equipped with an internal UV–Vis diode array detector (SPD-M20A), an external differential refractometer (Optilab T-rEX), and a multiangle light-scattering detector (DAWN HELEOS II, both Wyatt Technology, USA). TSK gel SuperAW3000 and SuperAW4000 columns (Tosoh Bioscience, USA) were used in series to analyze samples in a mobile phase of 80% methanol and 20% sodium acetate buffer (0.3 M, pH 6.5) at a flow rate of 0.6 mL·min−1. The dn/dc values of 0.125 mL·g−1 were used to calculate the molecular weights of the TMPC-based polymers.

NMR spectroscopy

The composition of polymers was determined by 1H-, 31P-, and 19F-NMR spectroscopy in deuterated solvents at 25 °C on a Bruker NEO spectrometer (Bruker, MA, USA) operating at 400, 376.48, and 161.97 MHz for 1H, 19F, and 31P, respectively. 1H-NMR spectra were calibrated to the signal of the internal standard tetramethylsilane (TMS) at δ = 0.00 MHz. Typical measurement conditions were as follows: 1H NMR: “zg” pulse sequence, π/2 pulse width 16.5 µs, relaxation delay 10 s, spectral width 12 kHz, scan time 2.75 s, 32 scans. 19F NMR: “zg” pulse sequence, π/2 pulse width 19 µs, relaxation delay 3 s, spectral width 37 kHz, scan time 0.20 s, 128 scans. 31P NMR: “zgpg” pulse sequence, π/2 pulse width 10 µs, relaxation delay 3 s, spectral width 71 kHz, scan time 2.99 s, 500 scans.

Cell lines

Cell lines were purchased from American Type Culture Collection® (Manassas, VA, USA). The PC3 cells were cultured in Dulbecco’s modified Eagle’s medium (DMEM) supplemented with Ham’s F-12 nutrient mixture (Gibco, Thermo Fisher Scientific, USA), 1% GlutaMAX (Gibco, Thermo Fisher Scientific, USA), 10% fetal bovine serum (FBS, Gibco, Thermo Fisher Scientific, USA), and 1% penicillin–streptomycin (Biosera, France). The 4T1, THP-1, and RAW 264.7 cell lines were cultured in RPMI 1640 media (Gibco, Thermo Fisher Scientific) supplemented with 2 mmol L−1 L-glutamine, 10% FBS, and 1% penicillin–streptomycin. All cells were incubated under standard conditions (T = 37 °C; 5% CO2).

ROS production under hypoxic conditions

To investigate extracellular ROS production, we employed 4T1 cancer cell line, as an in vitro model representing ROS-rich tissue. The cell line was cultured as described in the previous section. The 4T1 cell line was selected and tested for its relevance in an in vivo cancer model. For live-cell imaging, cells were seeded in a 96-well plate (2 × 106 mL−1) and incubated for 24 h. Subsequently, the cells were washed three times with phosphate-buffered saline (PBS, Gibco, Thermo Fisher Scientific) before changing the medium for FluoroBrite DMEM (Gibco, Thermo Fisher Scientific) containing 10 μmol  L−1 OB (Invitrogen, Thermo Fisher Scientific, USA) in triplicate. FluoroBrite DMEM was used in all measurements because it exhibits no background fluorescence. OB is a sensitive fluorogenic reagent that detects the extracellular release of oxidative products. Excited at 488 nm and emitted at 530 nm, the fluorescent product is formed by oxidation of the nonfluorescent substrate, where the rate of fluorescence increase is proportional to the number of oxidative species generated. The signal was detected using a fluorescence optical imager (AMI HT, Spectral Instruments, USA).

In order to establish the production of ROS within the cell line, both positive (using OB dye with 50 nM to 1 µM H2O2 range) and negative (using OB dye alone) controls were implemented. Additionally, hydrogen peroxide, at concentrations ranging from 50 nM to 1 µM, was introduced to the cells, dye, and culture medium to act as a positive control for measurement. Cellular imaging was conducted at various intervals over an 8-h period following staining. Image analysis and signal quantification were performed using ImageJ 1.48 (National Institutes of Health, Bethesda, USA) and Aura 4.0 (Spectral Imaging, USA) software, whereby the signal intensity was measured as the total emission (photons per second) within the designated region of interest (ROI). This measurement was repeated three times for each time point, and the ratio of signal intensity between the experimental and control groups was plotted against time.

MR instrumentation

MR experiments were performed employing the BioSpec 47/20 preclinical experimental 4.7 T and 14.1 T scanners (Bruker, Ettlingen, Germany). On 4.7 T scanner, characterization of the polymer was performed using a small, highly sensitive radiofrequency (RF) solenoid coil customized for 1H-, 19F-, and 31P-MR spectroscopy (diameter = 8 mm, length = 8 mm, 4 turns)4. The resonance frequency was continuously adjustable within a range of 80 to 210 MHz, corresponding to the respective Larmor frequencies of the 31P (81 MHz), 19F (188 MHz), and 1H (200 MHz) nuclei. This coil, due to its exceptional sensitivity and the small probe volume (V = 0.5 mL) required for high-quality 31P-MR signal quantification, was also deemed suitable for in vitro measurement of the polymer under oxidative conditions.

Measurements, which involved 1H-MR imaging, 19F-MR spectroscopy and imaging, and 31P-MR spectroscopy, were conducted using a combination of two surface RF coils. For anatomy analysis (1H-MRI) and probe localization (19F-MRI), a custom dual 1H/19F coil (diameter = 40 mm) designed for continuous tuning between 1H and 19F Larmor frequencies was utilized. The second coil (diameter = 30 mm), a rectangular half-saddle model optimized for in vivo mouse experiments, was used for 31P-MR measurements.

Additional measurements of the probe internalization were made using 14.1 T MR scanner with 1H/19F volume coil. The signal sensitivity of the probe on lower magnetic fields was measured using 3.0 T clinical MR scanner, and 7 T experimental MR scanner was used to confirm the phosphorus signal-detectability in vivo; in both systems commercial surface 1H/31P coils were used.

MR of the 31P-polymer under hypoxic conditions

In a previous study, we employed 31P-MRS alongside a combination of 1H- and 31P-MRI techniques to characterize a phosphorus-based 31P-polymer, determining its relaxivity and sensitivity. Furthermore, cytotoxicity testing of the polymer was conducted prior to in vivo measurement, revealing no toxic effects on the viability of two distinct cell cultures6. Herein, the oxidation of the 31P-polymer in vitro was tested to evaluate its sensitivity for 31P-MR signal changes using an RF solenoid coil. We investigated ROS-triggered chemical shift of the polymer under various oxidative conditions. For this investigation, we used the 31P-polymer containing solely the phosphorus P = S groups, as the simplicity of the cell line-based model does not require biodistribution monitoring. 31P-MR spectroscopy was performed using a single-pulse sequence (repetition time TR = 500 ms, ST = 5 min, bandwidth BW = 200 ppm) over a prolonged period of up to 24 h.

Initially, the 31P-polymer (cP = 10 mmol L−1; V = 0.4 mL in dH2O) was mixed with either H2O2 (c = 20 mmol L−1; mimicking hypoxic tumor tissue) or NaClO (c = 20 mmol L−1; mimicking bacterial inflammation). Subsequently, the same MR measurements were proceeded with the polymer (cP = 10 mmol L−1; V = 0.05 mL in PBS) added to a suspension of 4T1, PC3, and THP-1 cancer cell lines (average of 106.3 × 106 mL−1, with V = 0.35 mL of the respective cells in cell culture media). To prevent the creation of a strongly hypoxic environment, all cell measurements were performed in microcentrifuge tubes (V = 0.5 mL) with a sterile syringe filter (Ø 4 mm; 0.2-µm pore size; BRAND, Merck Life Science, Germany) securely attached to the tube’s top. The filter ensured aseptic conditions throughout the measurement while allowing for air exchange. Additionally, to exclude the influence of autoxidation, the polymer was measured in the cell-free culture medium under identical conditions (cP = 10 mmol L−1; V = 0.4 mL).

For the in vitro experimental setup, we used the 31P-polymer polymer carrying solely the phosphorus P = S groups, as biodistribution data were not required. Localization was measured using 1H-MR imaging employing a rapid acquisition with relaxation enhancement (RARE) sequence. Samples from the PC3 cell line were incubated in Eppendorf tubes at room temperature for subsequent measurements. Cell viability was assessed at three time points within 1 to 3 h of incubation utilizing an automated cell counter. The phosphorus-based probe relaxation times and MR parameters were based on results from our previous study (ref. 6): 1H-MR T1/T2 = 2510.0/2067.2 ms, 31P-MR T1/T2 = 2018.3/119.9 ms.

The sensitivity of the 31P-polymer (cP = 100 mmol L−1; V = 1.5 mL) and responsiveness to the ROS-rich environment (H2O2, V = 100 µL) was further tested on the clinical 3 T MR scanner using 31P-MR spectroscopy (single-pulse sequence, TR = 1000 ms, ST = 8 min, BW = 140 ppm). The measurements were done right after the addition of the H2O2 and after 24 h.

MR sensitivity and responsiveness of the dual 31P/19F-Polymer

A newly synthesized double 31P/19F-polymer was measured to validate the sensitivity, responsiveness, and stability of both phosphorus and fluorine signals under hypoxic conditions. The probe (cp = 10 mmol L−1; V = 0.4 mL in dH2O) underwent initial measurement using 31P/19F-MRS (19F: single-pulse sequence; TR = 500 ms, ST = 5 min, BW = 40 ppm; 31P: single-pulse sequence; TR = 200 ms, ST = 10 min, BW = 200 ppm). To confirm the chemical shift in both fluorine and phosphorus MR, the polymer was measured using 19F-MRSI (chemical shift imaging CSI sequence; TR = 200 ms, FOV = 35 × 35 mm, slice thickness = 10 mm, ST = 6–30 min) and 31P-MRSI (CSI sequence; TR = 200 ms, FOV = 35 × 35 mm, slice thickness = 10 mm, ST = 6–30 min) alongside 1H-MRI reference images (1H: RARE sequence, coronal plane, TR/echo time TE = 3300/11.7 ms, field of view FOV = 35 × 35 mm, slice thickness = 0.6 mm, ST = 5 m 16 s). Sensitivity was established based on repeat MRSI measurements with varying scan times. Finally, the polymer was measured with hydrogen peroxide (H2O2; c = 20 mmol L−1) to establish its responsiveness under hypoxic conditions compared to the 31P-polymer and the stability of the fluorine signal over a period of 24 h.

Additionally, 31P/19F-polymer (cp = 10 mmol L−1; V = 0.4 mL in dH2O) tested for cell (RAW264.7) internalization was measured using standard 1H-MRI reference images, 19F-MRS single-pulse sequence (only polymer; TR = 1000 ms, ST = 2 min 30 s, BW = 200 ppm) and 19F-MRS Point-RESolved Spectroscopy sequence (PRESS, TR = 1000 ms, ST = 1 h, BW = 50 ppm; polymer mixed with H2O2, cells treated with the polymer and the control cells).

In vivo MR

Animal protocols were approved by the Ethics Committee of the Institute for Clinical and Experimental Medicine and the Ministry of Health of the Czech Republic (No. 58/2014) in accordance with the European Communities Council Directive (2010/63/EU). Animals, provided by Animalab (Czech Republic), were housed in standard laboratory cages with a 12-h light–dark cycle in a conventional breeding facility, with ad libitum access to water and pelleted food. Isoflurane (Baxter, Deerfield, USA) was administrated for anesthesia during injections and MR experiments (5% for induction, 1.5 to 2% for maintenance). Respiratory function was monitored using a trigger unit (Rapid Biomedical, Berlin, Germany), and eye cream (Ophthalmo-Septonex, Zentiva, Czech Republic) was applied to prevent eye dryness. During MR measurements, animals were positioned in a custom coil holder heated with water-filled tubes to maintain a temperature of 37 °C.

To induce tumor growth in vivo, a cell suspension (0.5 × 106 4T1 cells; V = 0.1 mL in PBS) was subcutaneously injected into the right mammary fat pad of healthy female Balb/c mice. Animals were monitored daily once tumor volume exceeded 1 mL. For polymer biodistribution experiments (see section Proof-of-Principle In Vivo Biodistribution Based on 19F-MR), mice received I.V. injections (V = 0.15 mL in PBS) via the lateral tail vein or retro-orbitally via the venous sinus (V = 0.2 mL in PBS). In dual 31P/19F-MR experiments (see section MR Sensitivity and Responsiveness of the dual 31P/19F-Polymer), animals received I.T. injection of the polymer (31P/19F-polymer; cP = 100 mmol L−1; cF = 112.5 mmol L−1) to determine the influence of ROS on the probe. For all in vivo experiments, an aqueous solution of the polymer was injected.

Proof-of-principle in vivo biodistribution based on 19F-MR

In vivo investigations aimed to assess the biodistribution and efficiency of the 31P/19F-polymer in reaching the tumor via passive accumulation. Leveraging the EPR effect, inherent to tumors with compromised lymphatic drainage, these studies were conducted on Balb/c mice bearing established tumors. Injections were administrated at two different sites to evaluate delivery efficiency. Comparison between intravenous I.V. and R.O. injection methods were performed using the dual 31P/19F-polymer (V = 0.15 / 0.2 mL in PBS, respectively). Monitoring of the animals employed several MR methods, with the highly sensitive fluorine signal used as the distribution indicator. These techniques included 1H-MR imaging (RARE sequence, coronal plane, TR/TE = 3300/11.7 ms, FOV = 60 × 60 mm, slice thickness = 1.2 mm, ST = 1 m 19 s), 19F-MR spectroscopy (single-pulse sequence; TR = 150 ms, ST = 5 min, BW = 100 ppm), and 19F-MR imaging (CSI; TR = 150 ms, ST = 10–120 min, BW = 100 ppm). The dual 1H/19F RF surface coil was positioned beneath the tumor site. MR measurements were obtained at three time points: 6 h (day 0 + 6 h), followed by 24 h (day 1, R.O. injection) and 48 h (day 2, I.V. injection) PI.

Dual 31P/19F in vivo MR under hypoxic conditions

Animal monitoring was conducted daily throughout the study. Once tumor volume reached 1.6 ± 0.6 mL, animals (N = 5) received an I.T. injections of the 31P/19F-polymer (V = 0.2 mL in PBS). To investigate ROS-triggered chemical shifts and to track polymer degradation in vivo, three MR methods were used: 1H-MR imaging (RARE sequence, coronal plane, TR/TE = 3300/11.7 ms, FOV = 40 × 40 mm, slice thickness = 1.3 mm, ST = 1 m 19 s), 31P/19F-MR spectroscopy (single-pulse sequence; TR = 200/500 ms, ST = 10/5 min, BW = 200/40 ppm), and 19F-MR imaging (CSI; TR = 200 ms, ST = 1 h 8 m, BW = 40 ppm). Initially, the dual 1H/19F RF surface coil was positioned beneath the tumor site. Subsequently, it was replaced with a phosphorus RF surface coil while maintaining the same animal holder to ensure data repeatability. MR measurements were performed immediately after injection (t = 0.5 h) and repeated at 24- and 48-h PI.

Quantification of MR imaging and spectroscopy data

Data processing and quantification for both 31P/19F-MR spectroscopy and 1H/19F-MR imaging was primarily carried out using custom-written scripts developed in Matlab (Matlab R2021b, MathWorks, USA). The scripts facilitated the simultaneous processing of time series data, including nonlocalized measurements. Peak amplitude (for in vitro data) or integral (for in vivo data) was used to determine the relative concentration of 31P nuclei (P = S signal, with a chemical shift of ∆δ ~ 60 ppm from the physiological signal) or fluorine signal (CF3 signal, with a chemical shift of ∆δ ~ 20 ppm from the isoflurane). The same ppm range was applied for both signal and noise calculations. Apodization techniques were not applied during quantification to avoid potential spectral distortion. Evaluation of in vivo “hotspot” 19F-CSI sequences involved identifying the resonance frequency range of fluorine, employing matrix normalization to enhance contrast in the reconstructed CSI image, suppressing the background noise, and overlaying the 1H-MRI reference and 19F-CSI image. For extended in vitro measurements, the 31P-MRS signal was averaged over each hour of the experiment and expressed as a percentage change in signal amplitude relative to the experiment onset. In vivo 19F- and 31P-MRS data were quantified using an integral (I) ratio of signal (S) and noise (N), calculated as SNRMRS \(=\frac{{S}_{I}}{{N}_{I}}\) (1). Due to the overlapping frequencies of the physiological phosphorus signal (81.157 kHz), quantification of the total conversion of the phosphorus signal to the P = O groups was not feasible. Instead, the amplitude or integral of the P = S phosphorus MR signal was evaluated. Quantification of the 19F-CSI signal and background noise was performed using ImageJ software, and the SNR was calculated as \({{{\rm{SNR}}}}_{{{\rm{MRI}}}}=\frac{S}{{\sigma }_{s}}\cdot 0.655\) (2), where S is the signal intensity in ROI, σ is the standard deviation of background noise, and the constant 0.655 accounts for the Rician distribution of background noise in the magnitude MR image63.

Conclusion

This study introduces ROS-sensitive probes derived from hydrophilic phospho-/fluoropolymers for application in X-nuclei MR. Our results demonstrate their reliable monitoring via 31P/19F-MR techniques, serving as sensitive 31P-MR sensors capable of detecting ROS overproduction in specific pathologies, observed even at magnetic field strengths used in clinical practice. The probe’s design includes a thiophosphoester groups (P = S), which exhibits a distinct chemical shift relative to signals from naturally occurring biomolecules, making it detectable in vivo. The P = S groups acts as an in situ ROS detector, with oxidation leading to a detectable 31P-MR chemical shift change. Furthermore, the incorporation of a trifluoromethyl groups (CF3) aids in localizing the probe by 19F-MR, offering precise on-site information regarding pharmacokinetics and distribution data within the body with high specificity, reaching 100%.

Our findings highlight the probe’s accumulation at tumor sites and its in vivo responsiveness, as indicated by natural clearance and ROS-induced oxidation. The MR-based localization and functionality of this exogenous probe, even at low concentrations in vivo, show promise as a versatile tool for functional and on-site localization using 31P/19F-MR imaging. With unique properties including distinct chemical shifts, ROS scavenging capabilities, and biodistribution tracking, this probe holds significant potential for elucidating oxidative stress’s role in disease and exploring targeted therapeutic ROS-based interventions. Consequently, it represents an innovative approach to responsive 31P-MR, complementing traditional 1H-MRI anatomical information by providing insights into tumor physiology.

Reporting summary

Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.