Abstract
Axion-like particles (ALPs) arise from well-motivated extensions to the Standard Model and could account for dark matter. ALP dark matter would manifest as a field oscillating at an (as of yet) unknown frequency. The frequency depends linearly on the ALP mass and plausibly ranges from 10−22 to 10 eV/c2. This motivates broadband search approaches. We report on a direct search for ALP dark matter with an interferometer composed of two atomic K-Rb-3He comagnetometers, one situated in Mainz, Germany, and the other in Kraków, Poland. We leverage the anticipated spatio-temporal coherence properties of the ALP field and probe all ALP-gradient-spin interactions covering a mass range of nine orders of magnitude. No significant evidence of an ALP signal is found. We thus place new upper limits on the ALP-neutron, ALP-proton and ALP-electron couplings reaching below gaNN < 10−9 GeV−1, gaPP < 10−7 GeV−1 and gaee < 10−6 GeV−1, respectively. These limits improve upon previous laboratory constraints for neutron and proton couplings by up to three orders of magnitude.
Similar content being viewed by others
Introduction
Abundant astrophysical and cosmological observations at different scales1,2,3 suggest that about 85% of the matter in the Universe does not noticeably interact beyond gravitational interactions and is thus known as “dark” matter (DM). Since the DM composition remains unknown, it serves as a provocative indication of physics beyond the Standard Model (SM) and drives the search for hypothetical DM particles.
Ultralight (≲10 eV/c2) pseudoscalar bosons known as axion-like particles (ALPs) are particularly well-motivated DM candidates4,5,6,7. ALPs could account for the correct abundance of relic DM (via, for example, a misalignment mechanism8), and a subset of them could resolve the strong-CP problem9. Additionally, ALPs can interact with SM particles through couplings to photons, gluons, and fermions10, offering direct ways of probing their existence11,12,13.
In this article, we present the results of an interferometric ALP search (see also refs. 14,15). The search explores a wide mass range (nine orders of magnitude) and investigates ALP couplings to three distinct spin types (i.e., those associated with proton, neutron, and electron). The interferometer is composed of two K-Rb-3He atomic comagnetometers, one located at the Jagiellonian University in Kraków, Poland16 and the other, separated by 860 km, at the Johannes Gutenberg University in Mainz, Germany, see Fig. 1a. The interference occurs through the phase-sensitive combination of the amplitude data, in a manner similar to that used in radio telescope networks (e.g., the event horizon telescope17). The main difference between our and other schemes is that we are sensitive to ALP DM gradients rather than electromagnetic waves, and that the corresponding improvement in angular resolution does not play a role in searching for DM, which is assumed to have a homogeneous local density. It might, however, be important in searches when DM models feature more heterogeneous mass distribution, including streams and halos18,19,20,21, or if there are distinguishable emitters of bosonic fields in the Universe, e.g., black holes emitting ALPs in a process of superradiance22 or during binary merger23. The interference increases the signal-to-noise ratio of the search compared to a single sensor24. This work constitutes the first constraints from an interferometer composed of two comagnetometers.
a The two devices comprising the interferometer are indicated in their respective locations in Mainz and Kraków. The small red arrows at the Earth’s surface point in the directions of the sensor sensitivity axes. In our model, Earth is moving in the galactic rest frame at velocity vE through the ALP DM field, characterized by its de Broglie wavelength λDB, that is more than a thousand times larger than the Earth’s radius. Besides its translational motion, Earth rotates around its axis, giving rise to sidereal modulation of the signal at the frequency ωE. Base image: Google Earth. Image ©2025 Google, Image Landsat / Copernicus, Data SIO, NOAA, U.S. Navy, NGA, GEBCO, IBCAO. b Orientation of the sensitive axes of the comagnetometers with respect to Earth’s rotation axis. The sensitive axes of the comagnetometers can be decomposed into components along and perpendicular to the Earth’s rotation axis. The former results in an ALP signal component (carrier) arising at the ALP Compton frequency ωa, while the latter results in (generally asymmetric) sidebands separated from the carrier by the sidereal frequency ωE. c Signal interferometry in the data analysis (illustration). The points in the three subfigures correspond to the complex Fourier amplitudes of all probed frequency bins of the Mainz (left), Kraków (middle) datasets, and their combination (right). The frequency points are intended for illustration purposes and do not correspond to experimental data. We assume normal noise distributions. The circles indicate the standard deviation. The points marked with red, blue, and orange represent injected ALP signatures observable in both comagnetometers and how they appear in the combined signal. Due to the directional sensitivity of the comagnetometers, the injected ALP signal manifests as a carrier of amplitude AK only in the Kraków data, and sideband signatures of different amplitudes and phases in both Kraków (\({A}_{\pm }^{{{\rm{K}}}}\)) and Mainz (\({A}_{\pm }^{{{\rm{M}}}}\)) data. The phase difference between the signals arises due to the different orientation of the sensitive axes (π/2), as well as the different locations (ϕ) of the sensors. Appropriate phasing allows to coherently add the ALP signals, while the noise adds incoherently.
We optimize both comagnetometers to operate in the self-compensating regime25,26,27. To a first order, the devices are insensitive to low-frequency magnetic-field variations, but retain sensitivity to non-magnetic spin interactions28,29. This makes them excellent tools for probing the interaction of the galactic ALP DM field a(r, t) with neutron spins σN, proton spins σP and electron spins σe, which are described by the Hamiltonians
where gaNN, gaPP, and gaee are unknown coupling constants to neutrons, protons, and electrons. Self-compensating comagnetometers have already established the most stringent limits in certain mass ranges, even surpassing astrophysical constraints30,31,32. In this work, we search in experimentally unconstrained ALP parameter space in the ultralight mass range below 10−13 eV/c2.
If the estimated local DM density (≈0.4 GeV/cm3)33 is mostly due to an ALP of mass ma, the occupation number of the ALP field would be large, and hence it can be approximated as a classical field oscillating near the ALP Compton frequency34. In this model, the characteristics of the oscillating ALP field, such as the amplitudes and the phases of the ALP-gradient components, fluctuate in time according to the properties of virialized DM35,36,37,38,39. The characteristic time scale of the fluctuations results from the ALP DM velocity spread, which leads to a coherence time of around 106 oscillations of the field (for example, about 15 years for ma = 10−17 eV/c2).
In our work, we focus primarily on the regime where the coherence time of the ALP collective oscillation is larger than the total measurement time. In this regime, the ALP field can be treated as having a constant amplitude and direction, and hence its signatures at the two sensor locations are highly correlated. For reference, an ALP particle of mass 10−17 eV/c2, assuming a relative velocity equal to that of Earth in the galactic rest frame, has a de Broglie wavelength of ~103 astronomical units. Thus, by properly combining the signals from both stations, the ALP signals will be added constructively, while the effects of local noise fluctuations sum incoherently and are suppressed, see Fig. 1c.
An additional analysis of the results allows us to extend the search to ALP masses below ~5 × 10−20 eV/c2. This is possible by looking for spectral signatures in the data that would arise due to the rotation of the Earth. The properties of the field gradient in this ultra-low frequency regime are discussed, and the signal properties are explicitly reviewed below.
This article is structured as follows. In the section “Signal model,” we review the ALP DM signal model, explicitly showing the expected signatures in the frequency domain for a daily modulated sensor, and discuss how the sensitivity can be improved by analyzing interfering signals from multiple sensors. In the section “Search strategy and results,” we show the analysis framework and discuss how data is combined to maximize a signal-to-noise ratio. As no ALP candidates are found, we set limits on the ALP DM pseudoscalar spin interactions in the section “Setting limits.” The experimental setup and some technical details of the search are presented in the section “Methods.”
Results and discussion
Signal model
To describe the expected signal model in the two comagnetometer locations, we utilize the framework described in refs. 30,37,38. Due to its high occupation number, the ALP field can be approximated as a sum of N independent oscillations. We write the components of the ALP field gradient at position r and time t in a Cartesian frame of reference i = x, y, z, where the Solar System is at rest
The negative sign in the second line is absorbed by the random phase \({\phi }_{n}={\phi }_{n}^{{\prime} }+\pi \), c is the speed of light, ma is the ALP mass, ρDM ≈ 0.4 GeV/cm333 is the local DM density, kn = mavn/ℏ is the ALP-field wave vector, ωn is the angular frequency of each oscillating mode n, and \({({{{\boldsymbol{v}}}}_{n})}_{i}\) is the i-th component of the relative velocity vn between the ALP mode and the sensor. Assuming that ALPs are virialized in the Milky Way, the velocities vn follow a 3D normal distribution centered at zero in the galactic frame. On Earth, the observed velocity distribution will be offset by Earth’s velocity in the galactic frame \({({{{\boldsymbol{v}}}}_{{{\bf{E}}}})}_{i}\). We neglect effects due to the movement of Earth within the Solar System, as it is negligible compared to the velocity of the Solar System in the galaxy38. The velocity components \({({{{\boldsymbol{v}}}}_{n})}_{i}\) are then distributed according to
where v0 ≈ 220 km/s is the virial velocity in the Milky Way, determining the variance of the velocity distribution to be \({v}_{0}^{2}/2\). The DM escape velocity is neglected, since it has a negligible effect on the distribution.
Each mode of the ALP field experiences a kinetic energy correction, leading to a small frequency shift \({\omega }_{n}\approx {\omega }_{a}(1+{{{\boldsymbol{v}}}}_{n}^{2}/2{c}^{2})\). Thus, most of the ALP spectrum is concentrated within a spectral width given by38
The collective mode can be described by a nearly monochromatic oscillation with independent amplitude and phase for each orthogonal spatial direction. The amplitudes and phases are random and evolve smoothly on time scales set by the coherence time τ ≈ 2π/Δω. The underlying probability distributions of the amplitudes and phases can be derived from Eqs. (2) and (3)38. This results in six independent parameters: three amplitudes (αx, αy, and αz), following Rayleigh distributions, and three phases (ϕx, ϕy, and ϕz), following uniform distributions over [0, 2π)37. Because the ALP de Broglie wavelength in the analyzed mass range is much larger than the sensor separation, λ = 2π/kn ≫ d = 860 km, we neglect the spatial dependence, i.e., kn ⋅ r ≈ 0, in Eq. (2) for both sensors. The ALP gradient can then be written as
where ωa is the Compton angular frequency of the ALP. The sum can be evaluated with the central limit theorem, and results in the amplitude terms αi. The probability distributions of the amplitudes αi are given by38
where α is a Rayleigh distributed random number with scale parameter equal to one.
The sensitive axis \(\hat{{{\boldsymbol{m}}}}\) of a single sensor located at Earth’s surface rotates with the sidereal frequency of Earth, ωE. The coordinate system is chosen such that the \(\hat{{{\boldsymbol{z}}}}\) component is parallel to the Earth’s rotation axis and the \(\hat{{{\boldsymbol{x}}}}\) component is perpendicular to the Greenwich meridian. The coordinate system can be assumed static in the galactic rest frame over the timespan of the experiment. This results in a fixed mz component and daily modulated mx and my components:
where \(\theta=\angle (\hat{{{\boldsymbol{z}}}},\hat{{{\boldsymbol{m}}}})\) is the polar angle and \({\phi }_{{{\rm{E}}}}=\angle (\hat{{{\boldsymbol{x}}}},\hat{{{\boldsymbol{m}}}})\) is the azimuthal angle in a spherical Earth coordinate system. The experimental signal is proportional to the projection of the gradient of the ALP field on the sensitive axis of the sensor.
The pseudomagnetic field in the experiment is given by \({B}_{a}=\frac{{g}_{{{\rm{eff}}}}}{{\mu }_{n}}{{\boldsymbol{\nabla }}}a\cdot \hat{{{\boldsymbol{m}}}}\), with μn/2π = −32.4 MHz/T the gyromagnetic ratio of 3He, and geff = gaNNξN (gaPPξP) the effective nucleon coupling taking into account the neutron (proton) content ξN (ξP)40. In the case of an electron interaction, the effective coupling is given by the ratio of the gyromagnetic ratios of electron and neutron geff = gaeeγn/γe (see the section “Comagnetometer response to exotic electron interaction”).
To obtain the frequency-domain signature of Eq. (8), we describe the three frequency components of the amplitude-modulated signal as a carrier, oscillating at the ALP Compton frequency ωa and two sidebands, separated from the carrier by Earth’s sidereal frequency ±ωE. The magnitudes of the three components (in magnetic-field units) are given by
Because there are three complex amplitudes A and A± that depend differently on six random variables αi and ϕi, the amplitudes are independent of one another. It is worth noting that even though the signal in the different frequency components is a result of an amplitude modulation, the sideband amplitudes are generally asymmetric. However, for measurements that average a large number of coherence times, the sideband magnitudes converge to the same value.
Note that the total power of the gradient of the ALP DM signal within a single coherence patch distributed among three frequencies ωa, ω+, and ω− is
where α = (αx, αy, αz) gives the 3D amplitude of the ALP DM field.
In our experimental search for ALP DM, it is essential to consider the role of noise in the comagnetometer data. Correlated measurements of ALP DM with two sensors instead of a single sensor lead to a substantial improvement in sensitivity. In fact, the improvement is greater than a factor of \(\sqrt{2}\) expected from two measurements of a quantity with uncorrelated noise24,41. The reason lies in the respective orientation of the sensitive axes of the sensors. In our configuration, the combination of both sensors allows access to all spatial components of the ALP-gradient signal.
The individual ALP-gradient components are independent random values described by Rayleigh distributions. Probing all of them simultaneously using the ALP DM interferometer configuration enables us to increase the combined signal amplitude and extend the range of the search into lower values of geff.
The spatial configuration of the two-station ALP DM interferometer is as follows: the sensitive axis of the Mainz station is horizontal in the laboratory pointing East in the Earth rotation plane (θM = 90° ± 1°), and therefore, is exclusively sensitive to the sideband signal A±. In contrast, the sensitive axis of the Kraków station is horizontal in the laboratory pointing North (θK = 50° ± 1°). The Kraków comagnetometer is therefore sensitive to all ALP spectral signatures (carrier and sidebands). The uncertainties on the angle are negligible compared to the statistical noise of the experiment.
Search strategy and results
In our experiment, we searched for ALP DM with Compton frequencies up to 11.6 Hz. In this frequency range, the linewidth of the ALP signal is below the frequency resolution of the analysis method. Additionally, the sensitive axes of the comagnetometers are modulated at the Earth’s sidereal frequency, ωE/2π ≈ 11.6 μHz, resulting in resolvable sidebands, see Eq. (9). The expected amplitude ratio between the central peak (carrier) and sidebands is given by the components of the sensitive axes parallel (carrier) and perpendicular (sidebands) to the rotation axis of Earth.
The data analyzed in this work correspond to a total of 40 25-h segments in Mainz and 28 25-h segments in Kraków, collected over a 92-day period between January 6 and April 7, 2024. Data collection was performed as consistently as possible, but several technical interruptions occurred during the measurement campaign. From that data, 25-h continuous data segments were used for the analysis, ensuring sidereal frequency resolution (Δω ≲ ωE).
In general, when searching for unknown dynamic observables, it is crucial to precisely know the sensor frequency response. However, in the case of ALP DM, the frequency response cannot be directly measured. To address this issue, the frequency responses of both comagnetometers to exotic interactions were inferred using the method reported in ref. 29. The method involves (1) measuring the response to a magnetic step perturbation, (2) fitting the Discrete Fourier Transform (DFT) data with a model that describes the coupled spin dynamics, and (3) inferring the frequency response of neutrons, protons, and electrons to postulated non-magnetic (exotic) interactions. In our analysis, the frequency responses were determined for each 25-h data segment. The calibration-fit results for Mainz and Kraków are summarized and discussed in the section “Experimental setup.”
The DFT is applied to a uniform timeseries of 25-h duration with a rectangular window to generate a DFT subset. To coherently combine ALP DM signals from different DFT subsets, a frequency-dependent shift is applied, and the subsets are phase aligned. Then, all DFT subsets of the respective station are averaged, resulting in a mean value and its standard deviation. We confirmed that the time-shifted DFT averaging procedure had no effect on the Fourier coefficients of injected oscillations.
To search for ALP DM signals [Eq. (10)], we construct an estimator of signal amplitude S(ω). To achieve the optimum signal-to-noise ratio, we extract all potential ALP DM signatures from the data by combining the Mainz and Kraków DFT datasets. We then combine the power of the carrier and sidebands. Cross-correlated combination of spatially distributed measurements has been performed previously, e.g., ref. 42. In this case specifically, the complex Fourier components of the sidebands (A±) in Mainz and Kraków are added with weights taking into account the direction of the sensitive axes and the noise level (see the section “Weights of the ALP signal estimator S(ω)”). The interfered sideband signal then reads
where \({a}_{\pm }^{i}\) are the weights with ± designating the higher (+) and lower (−) frequency sideband and superscript i = M, K indicates the Mainz and Kraków stations, respectively. The angle between the positions of the Mainz and Kraków comagnetometers in the rotation plane of the Earth is ϕ, see Fig. 1b. Accounting for the angle ϕ is required to ensure constructive interference of an oscillating ALP DM signal recorded in the two comagnetometers. The constructive interference of the ALP DM signal in the combination of the sidebands is illustrated in Fig. 1c.
Next, we combine the carrier in Kraków AK with the interfered sideband signal \({A}_{\pm }^{K+M}\). The signal estimator S(ω) for ALP DM incorporates the appropriate weights for averaging signal power; bK for the carrier in Kraków and \({b}_{\pm }^{K+M}\) for the upper and lower interfered sideband, see the section “Weights of the ALP signal estimator S(ω).” The Mainz carrier signal does not contribute to the signal estimator S(ω), as its weight bM ≈ 0, because \(\cos ({\theta }_{M})\approx 0\), meaning that there is no contribution to AM from ALP DM. The estimator for the ALP DM signal S(ω) is defined in the following way
Note that the standard deviation of the DFTs is propagated accordingly, resulting in an uncertainty in the signal estimator ΔS(ω) for each frequency.
The value of S(ω), given in magnetic-field units and determined from the acquired data, is represented by the blue points in Fig. 2. An ALP DM signal in the S(ω) data would correspond to a single data point at frequency ωa. Since this is one point out of the whole dataset consisting of a million points, one per frequency, the distribution of S(ω) over all frequencies characterizes the technical noise of the interferometer.
The results are shown as a function of frequency in the upper figure. The data shows a 1/f scaling behavior up to 10−2 Hz consistent with the technical noise of the apparatus. The peak sensitivity of the estimator reaches 10−17 T. No ALP candidate is found beyond the global 95% significance threshold in p value, as shown in the lower plot.
In order to estimate the expected value of the technical noise amplitude at each frequency, fit(ω), we use the measured values of S(ω) at surrounding points. For frequencies below 0.1 Hz, the mean is inferred from a global fit assuming a 1/f noise model. Above 0.1 Hz the mean is based on the moving average of 500 consecutive points centered around (but excluding) the frequency of interest. Figure 2 shows the mean of the technical noise as an orange line determined as discussed above, as well as a light red line indicating the 95% global significance threshold for each frequency.
To determine whether any of the estimator data points are significantly larger than expected from the measured technical noise, a detection threshold is established. The set of the signal-estimator values S(ω), normalized with the expected noise at each frequency, is found to match a non-central χ2 distribution with six degrees of freedom (see the section “Noise distribution and signal insertion demonstration”). The fitted non-central χ2 distribution is used to set the detection threshold to guarantee that a candidate signal has only a 5% global chance of arising due to technical noise, which accounts for the look-elsewhere effect. The measured values of S(ω) are consistent with noise and therefore show no evidence of an ALP DM candidate.
For ALP DM with frequencies below ωE, a different search approach is used. An ALP DM contribution at ωE would be observed for the Compton frequencies ωa < ωE even if ωa cannot be directly resolved in our data. This is due to the fact that the Earth’s rotation is modulating the ALP field that would be measured in the experiment, so there would always be a signal oscillating at Earth’s sidereal frequency ωE. Similar analysis techniques have been proposed previously43,44,45 that did not take into account the stochasticity of the ALP field. The width of each frequency bin is approximately equal to ωE. In this situation, the sidebands are at ωE ± ωa. Since ωE > ωa, they appear in the same frequency bin at ωE. By examining the frequency bin at ωE, the ALP search can be extended to the limit where the ALP oscillation is much slower than the rotation of Earth (ωa ≪ ωE). Due to the particular characteristics of this bin, we do not include it in the general ALP DM search described in the previous paragraph. Instead, we add Mainz and Kraków amplitudes with their respective weights and obtain AK+M(ω) following Eq. (11). We use the estimator AK+M(ω)/ΔAK+M(ω) normalized by the standard deviation ΔAM+K(w) as the expected noise model. For the frequency bins below 0.1 Hz the estimator histogram follows a Rayleigh distribution, which is used to calculate the detection threshold (95% local significance threshold) for the measured value AK+M(ωE). The results are shown in Fig. 3. The measured amplitude at ωE is S(ωE) = 4.7 × 10−14 T, and the standard deviation is ΔS(ωE) = 4.2 × 10−14 T. The standard deviation is calculated from the value of the Fourier coefficients at ω of each of the 25-h segments. Then, it is propagated following the definition of S(ω). It is consistent with noise and therefore shows no evidence of an ALP DM candidate.
For an ALP field oscillating below ωE, the sidebands are not resolved, and an ALP signature is present at ωE. However, AM+K(ωE) is compatible with the expected noise distribution and thus no ALP candidates with frequencies ωa < ωE are reported. The blue arrow indicates the frequency bin at ωE, the dashed red line indicates the 95% confidence detection threshold, and the orange distribution is the measured noise for the frequency bins between ωE and 0.01 Hz. The amplitude is normalized by the standard deviation ΔAM+K(ω) to whiten the noise.
Setting limits
Since our measurements did not reveal any ALP DM candidates in the frequency range below 11.6 Hz, we proceed to set limits on the ALP DM pseudoscalar couplings. Specifically, we set exclusions on the ALP-proton coupling gaPP, ALP-neutron coupling gaNN, and ALP-electron-coupling gaee. For simplicity, when constraining one of the three couplings, we do not consider interactions due to the other couplings. We describe the exclusion strategy for a generic geff coupling to the spin. For proton and neutron couplings, geff is rescaled by the respective nucleon contributions ξP and ξN to the total nuclear spin to get the final exclusions for gaPP = geff/ξP and gaNN = geff/ξN. The values for 3He of the nuclear content are ξN and ξP are calculated by using by using the Full-scale shell model, according to ref. 40. Table 1 shows the values for the nuclear contents and the gyromagnetic ratios γN and γe, among other relevant parameters.
The electron-coupling frequency response of the setup depends on the effect of the magnetic shield. While the effect of the shield on the ALP field itself can be neglected, the electron spins in the ferromagnetic shield “see” the exotic field effectively as a weak magnetic field. The shield generates an actual magnetic field in its inner volume to compensate. Therefore, within the shielded volume, we have both the ALP field and the real magnetic field produced by the shield46.
The frequency-dependent response of the comagnetometer to this combination of fields is discussed in the section “Comagnetometer response to exotic electron interaction.” Below, the Larmor precession frequency of 3He (≈3 Hz), the comagnetometer is, by design, insensitive to magnetic fields and its frequency response to the ALP field29 is the same as the nuclear frequency response but rescaled by the gyromagnetic ratio of the electron gaee = geffγN/γe.
To compute upper limits on the ALP-coupling strength, the statistical properties of the technical noise distribution and the distribution of ALP DM signatures in the signal estimator S(ω) have to be considered. The ALP DM signal distribution \({S}_{{g}_{{{\rm{eff}}}}}(\omega )\), given an effective coupling geff, is obtained by performing Monte Carlo simulations based on Eq. (12). It accounts for the stochastic properties of ALP DM (section “Signal model”) according to Eq. (9).
We use the Confidence Levels (CLs) method47, commonly used in new particle searches since ref. 48 to determine the limits on the coupling strength geff. If the measured value S(ω) is purely due to noise, it can be represented by a random number Xn drawn from a non-central χ2 distribution with a scale parameter determined by the expected value based on the neighboring points (1/f fit for frequencies below 0.1 Hz and moving average for frequencies above). The potential contribution to S(ω) from an ALP DM signal can also be represented by a random number accounting for its stochastic nature. We compute this with Monte Carlo simulations and scale the ALP DM distribution with the interaction strength geff. Finally, we add the noise distribution to the signal distribution and draw from the combined distribution a random number XS+n.
A certain value of geff is excluded with CL = 95% at frequency ω when
where \({\mathbb{P}}\) indicates the probability. The condition described by Eq. (13) means that for the excluded value of geff, there is only a 5% relative probability that an ALP DM signal contributes to the measured value of S(ω).
The sidereal frequency bin at ωE is used to expand the search to frequencies below 10−5 Hz. Due to constraints on ALP DM density below ma = 10−22 eV/c212, the exclusion from the sidereal frequency bin is limited to the range from 2.4 × 10−8 Hz up to the sidereal frequency ωE/2π ≈ 1.1 × 10−5 Hz. In this range, the field is considered nearly constant (ωa ≈ 0). The derivation of the signal model in this regime, as well as for the intermediate regime, is shown in the section “Derivation of the ALP signal in the ultra-low oscillating regime ωa ≪ ωE.”
For frequencies around 10−1 Hz, the total measurement time is on the order of the ALP field coherence time \({\tau }_{{\omega }_{a}}\). The ALP oscillation is coherent for measurement times \(T\lesssim {\tau }_{{\omega }_{a}}/2.5\)36,41. In particular, for frequencies wa/2π ≳ 5 × 10−2 Hz the ALP field is not coherent over the entire measurement time (T = 92 days). Therefore, for frequencies above 5 × 10−2 Hz, we weaken our estimated constraints on the coupling constants by \(\sqrt{T/{\tau }_{{\omega }_{a}}}\) to account for the incoherent averaging, as discussed in ref. 11. We also consider that over several coherence times the stochastic amplitudes [αx, αy, and αz in Eq. 9] will change. When calculating \({S}_{{g}_{{{\rm{eff}}}}}(\omega )\) with MC simulations, we average the stochastic amplitudes over the number of coherence times during the total measurement time.
The final results of this work are constraints on proton, neutron, and electron ALP couplings gaNN, gaPP, and gaee, respectively. The excluded parameter space covers a frequency range from 10−8 to 11.6 Hz, corresponding to masses from 10−22 to 4 × 10−14 eV, a total of nine orders of magnitude. Figs. 4–6 show the constrained parameter space in the context of previous laboratory searches. We plot the constraints smoothed with a moving average to guide the eye (mean limits). The scatter of the constraint data is similar to that in Fig. 2. In the mass range between 1.2 × 10−17 and 4 × 10−17 eV, the exclusion improves previous constraints by 3–4 orders of magnitude in gaNN and gaPP. The constraints on gaee improve direct DM search constraint by up to one order of magnitude and confirm the exclusions from solar axions searches and stellar physics.
Note that we do not include the results of ref. 45 in Figs. 4 and 6. Reference45 presented a re-analysis of the comagnetometer data from the Princeton group acquired in three different experiments49,50,51. More recently, the Princeton group published their own re-analysis of their data30, which notes critical issues in the interpretation of their data not accounted for in ref. 45. We regard the Princeton analysis as the definitive interpretation of the data.
Both comagnetometers in Mainz and Kraków are part of the Advanced GNOME experiment52. With additional comagnetometers currently in development, the network is set to expand, significantly enhancing its sensitivity to both ALP DM and transient events in future science runs.
At the same time, this experiment is part of the CASPEr family of experiments44,53, significantly improving previous CASPEr results (up to seven orders of magnitude) while also extending the covered mass range, see Figs. 4 and 5.
Methods
Experimental setup
The interferometer is composed of two self-compensating comagnetometers located about 1000 km apart: one in Mainz, Germany, and the other in Kraków, Poland. The two self-compensating comagnetometers are similar to that reported in refs. 27,29. At the core of the Mainz (Kraków) comagnetometer system is a spherical cell heated to about 180 °C and mounted inside a four-layer magnetic shield. The cell is filled with 3 amg of 3He and 50 Torr of N2 and loaded with a drop of an alkali-metal mixture with 1% 87Rb and 99% natural-abundance K (molar fractions). Spins are optically pumped with a 30 mW/cm2 (50 mW/cm2) circularly-polarized light tuned to the center of the Rb D1 (D2) line. The readout is realized by monitoring the polarization rotation of a ~15 mW/cm2 (1 mW/cm2) linearly-polarized light detuned about 0.5 nm from the K D1 line. To reduce the influence of the magnetic-field noise at low frequencies, the comagnetometers are operated in the self-compensating regime25. To operate in this regime, a Bz (compensation) field of about 100 nT (50 nT) is applied in Mainz (Kraków). In the Mainz comagnetometer, we modulate the Bx field with an 80 Hz sine wave. The signal demodulated at that frequency exhibits a resonance that is used to lock the system to the compensation point and therefore follows slow drifts of the equilibrium compensation field27. The sensitivity of both comagnetometers to exotic nucleon couplings is estimated with a daily (every 25 h) calibration pulse according to the calibration procedure described in ref. 29. In the Kraków comagnetometer, the drifts from the compensation point are corrected depending on demand after applying the calibration pulse (see, for example, two groups of fitted values of ωe and ωHe in Fig. 7, corresponding to two time-separated datasets), while there is no such a correction procedure in Mainz. The response to the calibration pulse is fitted with such parameters as the amplitude of the response that relates the voltage output to pseudomagnetic fields, the detuning from the compensation point ΔBz, the Larmor frequency of both electron spin ωe, and 3He nuclear spin ωn and the relaxation rate of electrons Re (at the current stage of the work, nuclear relaxation Rn is ignored). Figure 7 summarizes the fit parameters for all 25 h datasets. As shown, there is little variance in the parameters during the whole run. The detuning from the compensation point, ΔBz remains below 5 nT, which is within 5% (10%) of the leading field ~100 nT (~50 nT) in Mainz (Kraków). The fitted parameters encode the effects of ambient drifts of the environment, such as temperature and external magnetic field, that affect the comagnetometer sensitivity. By recalibrating every 25 h, the effects of such drifts on the low-frequency noise floor of the comagnetometer are taken into account. A detailed discussion of the setup stability on shorter time scales is provided in Chapter 6 of ref. 16. The low-frequency calibration factor for Mainz and Kraków is displayed in Fig. 7.
Top: summary of the frequency-response-fit results used for sensor calibration in Mainz and Kraków: response function amplitude A, detuning from the compensation point ΔBz, alkali-metal and noble gas Larmor frequencies ωe and ωn, alkali-metal polarization relaxation rate Re (divided by 20 only for the better visualization with other parameters). The fit parameters are described in detail in ref. 29. Horizontal bars designate the median values of parameters, and the shaded regions extend to the first quartiles. Bottom: low frequency (DC) calibration factor changes over the measurement timespan.
Weights of the ALP signal estimator S(ω)
The weights used in the signal estimator [see Eqs. (11) and (12)] are defined in the following way
where \({a}_{\pm }^{i}\) and \({b}_{\pm }^{i}\) are the weights with ± designating the higher (+) and lower (−) frequency sideband, and index i = M, K, K + M indicates the Mainz, Kraków, and combined signal, respectively. The σA (\({\sigma }_{| A{| }^{2}}\)) represents the standard deviation of the Mainz and Kraków amplitudes (power) in the frequency bin of interest. For the interfered sidebands, the weights are resulting from error propagation of \({b}_{\pm }^{K+M}\) according to Eq. (11). The factor 2 in bM, bK and \({b}_{\pm }^{K+M}\) is given by the expected ALP DM signal in the carrier being twice the sidebands [Eq. (9)].
Noise distribution and signal insertion demonstration
In order to derive the global threshold and the limits, it is important to understand the expected distribution of the signal estimator S(ω). The signal power estimator S2(ω) is a sum of six squares of normally distributed numbers: the real and imaginary Fourier coefficients from three frequency bins. However, to compare noise at different frequencies, we normalize ("whiten”) each bin by the estimated mean noise, fit(ω). Note that the expected value of the noise is proportional to the standard deviation of S(ω), namely, ΔS(ω). The signal estimator excess square S2(ω)/ΔS2(ω) follows a non-central χ2-distribution, defined as \(Z={\sum }_{n=1}^{N}{X}_{n}^{2}\), where {Xn} is a set of normally distributed random numbers with different means and same variance. From propagation of errors, we have that ΔS2(ω) = 2S(ω)ΔS(ω). As S(ω)/ΔS(ω) = 2S2(ω)/ΔS2(ω), they both follow the same distribution. This is also the case for S(ω)/fit(ω) ~ S(ω)/ΔS(ω), which is the estimator used to calculate the global threshold and the limits. The fitted non-central χ2 distribution reproduces the histogram of S(ω)/fit(ω), especially its tail, which is critical for claiming detection, see Fig. 8.
It is obtained by dividing the signal estimator S(ω) by the expected noise, fit(ω). The global threshold at each frequency is determined by fitting the normalized signal estimator with a non-central χ2 distribution with six degrees of freedom. This enables the calculation of the limits according to Eq. (13). Note that the y-axis is on a logarithmic scale to show the tail of the distribution in more detail.
Let us now consider the modification of the distribution induced by an ALP DM signal. Both noise and ALP DM signal are expected to have the same distribution: Gaussian variables in both Fourier quadratures of the raw Fourier spectrum (before combining the Mainz and Kraków carrier and sidebands). We inject the ALP DM signal in the raw Fourier spectrum as a normally distributed random variable, and then the data are combined to obtain the signal estimator S(ω) [see Eqs. (11) and (12)].
Figure 9 shows the distribution of S(ω/2π = 11.1 mHz) with an injected ALP DM signal for different coupling strengths geff computed according to Eq. (9). To sample the stochastic ALP parameter space, we injected 106 different sets of random amplitudes αi and phases ϕi. The resulting distributions are the sum of the noise and ALP signal distributions. As shown, increasing geff increases the mean and the variance of the distribution, which has to be taken into account when setting limits.
We show the probability distribution function (p.d.f.) of the signal amplitude assuming three different effective couplings geff. The shapes of both noise and signal are the same, since they come from the same distribution. By changing the inserted effective coupling geff, S(ω) reaches above the detection threshold at this frequency. Due to the measurement time being shorter than the coherence time, this distribution is only sampled once, so it is possible that even for a large coupling strength, the amplitude might still be below the threshold.
Derivation of the ALP signal in the ultra-low oscillating regime ω a ≪ ω E
Consider a single station and a quasi-constant oscillating ALP field at ωa ≪ ωE. The expected signal, defined in Eq. (8), becomes (ignoring the constant terms)
Therefore, the oscillating signal expected in the sensor is driven only by the rotation of Earth at ωE with an amplitude
In contrast to the case of ωa > ωE [Eq. (10)], the ALP DM signal amplitude explicitly depends on the random phases ϕx and ϕy. In this regime, where ωa ≈ 0, there is a probability of measuring near a zero crossing of the oscillation (when \({A}_{{\omega }_{{{\rm{E}}}}}\approx 0\)).
We want to account for the reduction of signal amplitude due to sampling a fraction of the oscillation, when 0 < ωa < 1/(2πT), with T = 92 days being the total period when the measurements took place. Here, some of the ALP DM oscillation is still measured. We perform Monte Carlo simulations of the integrated power of the respective oscillation fractions. We define this factor as
where ϕx and ϕy are uniformly distributed phases between (0,2π]. They are sampled in a Monte Carlo procedure to estimate the distribution of κ for a given ωa. The constraints at a frequency ωa < ωE are given by the product of κ(ωa, ϕx, ϕy) and the signal distribution at ωE. Then, the limits are calculated by taking a 95% CL with the CLs method.
Figure 10 (left) represents the 95% CL of the factor κ depending on the ALP frequency.
Left: 95% Confidence Level on κ in a function of the ALP Compton frequency. The factor κ represents the reduction in sensitivity to an ALP oscillation when searching via the Earth’s modulation of the field and accounts for the random phase of the ALP field. It also reduces the sensitivity of the set limits accordingly. It reaches a minimum of 0.3. The black dashed line represents a κ factor of 1. Right: Comagnetometer frequency response to exotic electronic perturbations. Different shielding scenarios are shown in Mainz (top) and Kraków (bottom): unshielded (dashed), 50% shielded (dotted), fully shielded (dash-dotted). The neutron coupling frequency response (full line) is shown for reference.
Comagnetometer response to exotic electron interaction
As explicitly shown in ref. 29, the direct coupling of the ALP DM with electrons results in a frequency response that is significantly different from those of neutrons and protons. To accurately estimate the response of the system, one has to consider all possible manifestations of the ALP-electron interaction. The comagnetometer vapor cell is surrounded by a mu-metal shield that cancels the external magnetic fields. However, due to the electron-based mechanism of magnetic shielding, the mu-metal also responds to an exotic electron interaction and induces a “compensating” magnetic field inside the shield (the response of the shield in the case of an exotic electron perturbation has been discussed in ref. 46). For the purpose of searching for ALP-electron coupling in the analyzed frequency range, we assume that the ALP-electron shielding factor is of the order of the magnetic shielding factor.
The ALP-electron interaction for a comagnetometer and a mu-metal shield manifests in the following way. The shield generates an opposing real magnetic field as a response to the applied exotic effective field at the sensor position. For a comagnetometer inside the shield, the two fields are superimposed. The electron is influenced by both opposing (magnetic and exotic) fields such that the perturbation of the electron, and consequently its response, is canceled. However, the magnetic field generated by the shield is picked up by the 3He nuclear spins, which do not directly respond to the ALP-electron interaction. Hence, for 100% shielding (i.e., when the induced magnetic field is equal and opposite to the effective exotic field), the frequency response has the same shape as the comagnetometer response to exotic nuclear spin interactions. It is rescaled by the response of the electrons in the shield to the ALP interaction, which is assumed to be flat in the frequency range of interest, effectively attenuating the response by a factor γN/γe. This is the scenario we assume when setting the limits in Fig. 6.
In general, the nuclear and electron spin perturbation in the comagnetometer is different for arbitrary shielding factors, and then the self-compensating mechanism would not apply. However, an interesting case is when the shield responds only at a 50% level to the exotic electron coupling. In the framework of ref. 28, this corresponds to αe = 0.5 and αn = −0.5. In this case, although the magnetic and exotic interactions are equal in strength, they have opposing directions, and hence the comagnetometer remains sensitive to the electron exotic interaction. The shape of the frequency response is a combination of the electron and nuclear spin responses.
Figure 10 (right) shows the comagnetometer response for three different shielding scenarios. They converge at frequencies below the nuclear Larmor frequency (~3 Hz), since the nuclear spin dominates the dynamics in this regime. Thus, the limits on ALP-electron coupling of this work in this frequency range are almost invariant for any shielding. However, for searches beyond 11.6 Hz, the response changes significantly. For high frequencies (~100 Hz), the unshielded electron response is greater compared to the fully shielded response, and a detailed shielding model should be considered while setting limits. For reference, the nuclear spin response to exotic neutron interactions is also displayed in Fig. 10.
Data availability
The calibrated data for neutron interactions from Mainz and Kraków comagnetometers are publicly available in https://doi.org/10.6084/m9.figshare.28902860.
Code availability
The code that support the plots in this paper are available from the corresponding authors upon request.
References
Bertone, G., Hooper, D. & Silk, J. Particle dark matter: evidence, candidates and constraints. Phys. Rep. 405, 279 (2005).
Feng, J. L. Dark matter candidates from particle physics and methods of detection. Annu. Rev. Astron. Astrophys. 48, 495 (2010).
Gorenstein, P. & Tucker, W. Astronomical signatures of dark matter. Adv. High Energy Phys. 2014, 878203 (2014).
Antypas, D. et al. New horizons: scalar and vector ultralight dark matter. Snowmass 2021 White Paper. https://doi.org/10.48550/arXiv.2203.14915 (2022).
Abbott, L. & Sikivie, P. A cosmological bound on the invisible axion. Physics Letters B 120, 133 (1983).
Preskill, J., Wise, M. B. & Wilczek, F. Cosmology of the invisible axion. Phys. Lett. B 120, 127 (1983).
Dine, M. & Fischler, W. The not-so-harmless axion. Phys. Lett. B 120, 137 (1983).
Co, R. T., Hall, L. J. & Harigaya, K. Axion kinetic misalignment mechanism. Phys. Rev. Lett. 124, 251802 (2020).
Marsh, D. J. E. Axion cosmology. Phys. Rep. 643, 1 (2016).
Graham, P. W. & Rajendran, S. New observables for direct detection of axion dark matter. Phys. Rev. D 88, 035023 (2013).
Budker, D., Graham, P. W., Ledbetter, M., Rajendran, S. & Sushkov, A. O. Proposal for a Cosmic Axion Spin Precession Experiment (CASPEr). Phys. Rev. X 4, 021030 (2014).
Jackson Kimball, D. F. and Van Bibber, K. (eds) The Search for Ultralight Bosonic Dark Matter https://doi.org/10.1007/978-3-030-95852-7 (Springer International Publishing, Cham, 2023).
Graham, P. W., Irastorza, I. G., Lamoreaux, S. K., Lindner, A. & Bibber, K. A. V. Experimental searches for the axion and axion-like particles. Annu. Rev. Nucl. Part Sci. 65, 485 (2015).
Foster, J. W., Kahn, Y., Nguyen, R., Rodd, N. L. & Safdi, B. R. Dark matter interferometry. Phys. Rev. D 103, 076018 (2021).
Crescini, N. The fermionic axion interferometer. arXiv, Preprint at https://arxiv.org/abs/2311.16364 (2023).
Padniuk, M. Wide-Frequency-Range Atomic Comagnetometry to Search for Spin-Dependent Interactions Beyond the Standard Model PhD thesis, Jagiellonian University in Kraków (2024).
Collaboration, T. E. H. T. et al. First M87 Event Horizon Telescope Results. I. The shadow of the supermassive black hole. Astrophys. J. Lett. 875, L1 (2019).
Budker, D., Eby, J., Gorghetto, M., Jiang, M. & Perez, G. A generic formation mechanism of ultralight dark matter solar halos. J. Cosmol. Astropart. Phys. 2023, 021 (2023).
O’Hare, C. A. J., Pierobon, G. & Redondo, J. Axion minicluster streams in the solar neighborhood. Phys. Rev. Lett. 133, 081001 (2024).
Kryemadhi, A., Maroudas, M., Mastronikolis, A. & Zioutas, K. Gravitational focusing effects on streaming dark matter as a new detection concept. Phys. Rev. D 108, 123043 (2023).
Khlopov, M. Y., Sakharov, A. S. & Sokoloff, D. D. The nonlinear modulation of the density distribution in standard axionic CDM and its cosmological impact. Nucl. Phys. B Proc. Suppl. 72, 105 (1999).
Baryakhtar, M., Galanis, M., Lasenby, R. & Simon, O. Black hole superradiance of self-interacting scalar fields. Phys. Rev. D 103, 095019 (2021).
Dailey, C. et al. Quantum sensor networks as exotic field telescopes for multi-messenger astronomy. Nat. Astron. 5, 150 (2020).
Gavilan-Martin, D. et al. Notes on optimizing a multi-sensor gradient axion-like particle dark matter search. PoS COSMICWISPers2024, 041 (2025).
Kornack, T. W. & Romalis, M. V. Dynamics of two overlapping spin ensembles interacting by spin exchange. Phys. Rev. Lett. 89, 253002 (2002).
Wei, K. et al. Ultrasensitive atomic comagnetometer with enhanced nuclear spin coherence. Phys. Rev. Lett. 130, 063201 (2023).
Klinger, E. et al. Optimization of nuclear polarization in an alkali-noble gas comagnetometer. Phys. Rev. Appl. 19, 044092 (2023).
Padniuk, M. et al. Response of atomic spin-based sensors to magnetic and nonmagnetic perturbations. Sci. Rep. 12, 324 (2022).
Padniuk, M. et al. Universal determination of comagnetometer response to spin couplings. Phys. Rev. Res. 6, 013339 (2024).
Lee, J., Lisanti, M., Terrano, W. A. & Romalis, M. Laboratory constraints on the neutron-spin coupling of feV-scale axions. Phys. Rev. X 13, 011050 (2023).
Wei, K. et al. Dark matter search with a resonantly-coupled hybrid spin system. Rept. Prog. Phys. 88, 057801 (2025).
Xu, Z. et al. Constraining ultralight dark matter through an accelerated resonant search. Commun. Phys. 7, 1 (2024).
Workman, R. L. et al. Review of particle physics. Prog. Theor. Exp. Phys. 2022, 083C01 (2022).
Chadha-Day, F., Ellis, J. & Marsh, D. J. E. Axion dark matter: What is it and why now? Sci. Adv. 8, eabj3618 (2022).
Foster, J. W., Rodd, N. L. & Safdi, B. R. Revealing the dark matter halo with axion direct detection. Phys. Rev. D 97, 123006 (2018).
Centers, G. P. et al. Stochastic fluctuations of bosonic dark matter. Nat. Commun. 12, 7321 (2021).
Lisanti, M., Moschella, M. & Terrano, W. Stochastic properties of ultralight scalar field gradients. Phys. Rev. D 104, 055037 (2021).
Gramolin, A. V. et al. Spectral signatures of axionlike dark matter. Phys. Rev. D 105, 035029 (2022).
Flambaum, V. & Samsonov, I. Fluctuations of atomic energy levels due to axion dark matter. Phys. Rev. D 108, 075022 (2023).
Kimball, D. F. J. Nuclear spin content and constraints on exotic spin-dependent couplings. New J. Phys. 17, 073008 (2015).
Derevianko, A. Detecting dark-matter waves with a network of precision-measurement tools. Phys. Rev. A 97, 042506 (2018).
Jiang, M. et al. Search for dark photons with synchronized quantum sensor network. Nature Commun. 15, 3331 (2024).
Graham, P. W. et al. Spin precession experiments for light axionic dark matter. Phys. Rev. D 97, 055006 (2018).
Wu, T. et al. Search for axionlike dark matter with a liquid-state nuclear spin comagnetometer. Phys. Rev. Lett. 122, 191302 (2019).
Bloch, I. M., Hochberg, Y., Kuflik, E. & Volansky, T. Axion-like relics: new constraints from old comagnetometer data. J. High Energy Phys. 2020, 167 (2020).
Jackson Kimball, D. F. et al. Magnetic shielding and exotic spin-dependent interactions. Phys. Rev. D 94, 082005 (2016).
Read, A. L. Presentation of search results: the CLs technique. J. Phys. G Nucl. Part. Phys. 28, 2693 (2002).
Search for the standard model Higgs boson at LEP. Phys. Lett. B 565, 61 https://doi.org/10.1016/S0370-2693(03)00614-2 (2003).
Vasilakis, G., Brown, J. M., Kornack, T. W. & Romalis, M. V. Limits on new long range nuclear spin-dependent forces set with a K–3He comagnetometer. Phys. Rev. Lett. 103, 261801 (2009).
Brown, J. M., Smullin, S. J., Kornack, T. W. & Romalis, M. V. New limit on Lorentz- and CPT-violating neutron spin interactions. Phys. Rev. Lett. 105, 151604 (2010).
Lee, J., Almasi, A. & Romalis, M. Improved limits on spin-mass interactions. Phys. Rev. Lett. 120, 161801 (2018).
Afach, S. et al. What can a GNOME do? Search targets for the global network of optical magnetometers for exotic physics searches. Ann. Phys. 536, 2300083 (2023).
Garcon, A. et al. Constraints on bosonic dark matter from ultralow-field nuclear magnetic resonance. Sci. Adv. 5, eaax4539 (2019).
Mohr, P., Newell, D., Taylor, B. & Tiesinga, E. CODATA recommended values of the fundamental physical constants: 2022, version Number: 1 https://doi.org/10.48550/ARXIV.2409.03787 (2024).
Savukov, I. M. & Romalis, M. V. Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields. Phys. Rev. A 71, 023405 (2005).
O’Hare, C. cajohare/axionlimits: Axionlimits, https://cajohare.github.io/AxionLimits/; https://doi.org/10.5281/zenodo.3932430 (2020).
Abel, C. et al. Search for axionlike dark matter through nuclear spin precession in electric and magnetic fields. Phys. Rev. X 7, 041034 (2017).
Abel, C. et al. Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal. SciPost Phys. 15, 058 (2023).
Bhusal, A., Houston, N. & Li, T. Searching for solar axions using data from the sudbury neutrino observatory. Phys. Rev. Lett. 126, 091601 (2021).
Bloch, I. M. et al. Constraints on axion-like dark matter from a serf comagnetometer. Nat. Commun. 14, 5784 (2023).
Jiang, M., Su, H., Garcon, A., Peng, X. & Budker, D. Search for axion-like dark matter with spin-based amplifiers. Nat. Phys. 17, 1402 (2021).
Buschmann, M., Dessert, C., Foster, J. W., Long, A. J. & Safdi, B. R. Upper limit on the QCD axion mass from isolated neutron star cooling. Phys. Rev. Lett. 128, 091102 (2022).
Yan, H. et al. Constraining exotic spin dependent interactions of muons and electrons. Eur. Phys. J. C 79, 971 (2019).
Terrano, W. A., Adelberger, E. G., Lee, J. G. & Heckel, B. R. Short-range, spin-dependent interactions of electrons: a probe for exotic pseudo-goldstone bosons. Phys. Rev. Lett. 115, 201801 (2015).
Terrano, W. A., Adelberger, E. G., Hagedorn, C. A. & Heckel, B. R. Constraints on axionlike dark matter with masses down to 10−23 eV/c2. Phys. Rev. Lett. 122, 231301 (2019).
Aprile, E. et al. Search for new physics in electronic recoil data from xenonnt. Phys. Rev. Lett. 129, 161805 (2022).
Gondolo, P. & Raffelt, G. G. Solar neutrino limit on axions and kev-mass bosons. Phys. Rev. D 79, 107301 (2009).
Capozzi, F. & Raffelt, G. Axion and neutrino bounds improved with new calibrations of the tip of the red-giant branch using geometric distance determinations. Phys. Rev. D 102, 083007 (2020).
Acknowledgements
We would like to acknowledge Gary Centers, Wolfgang Gradl, Julian Walter, and Yuzhe Zang for helpful discussions. We acknowledge support by the German Research Foundation (DFG) within the German Excellence Strategy (Project ID 39083149); by work from COST Action COSMIC WISPers CA21106, supported by COST (European Cooperation in Science and Technology). S.P., M.P., and M.S. acknowledge the support from the National Science Center, Poland, within the OPUS program (2020/39/B/ST2/01524), and G.L. acknowledges support from the Excellence Initiative—Research University of the Jagiellonian University in Kraków. The work of D.F.J.K. was supported by the U.S. National Science Foundation under grant PHYS-2110388. The work of A.O.S. was supported by the U.S. National Science Foundation CAREER grant PHY-2145162, and by the Gordon and Betty Moore Foundation, grant DOI 10.37807/gbmf12248.
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Contributions
D.G.M. and G.L. performed the measurements, analyzed the data, and wrote the manuscript. M.P. and E.K. designed and built the comagnetometer setups in Kraków and Mainz and edited the manuscript. M.S. optimized the comagnetometer in Kraków and performed the calibration and initial steps of the analysis. N.L.F. contributed to data analysis and writing the manuscript. A.O.S. edited the manuscript. D.F.J.K., S.P., and D.B. supervised the research and edited the manuscript. A.W. designed and built the comagnetometer setup in Mainz, conceptualized and supervised research, and wrote the manuscript. All authors contributed with discussions and checking the paper.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks the anonymous reviewer(s) for their contribution to the peer review of this work. A peer review file is available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gavilan-Martin, D., Łukasiewicz, G., Padniuk, M. et al. Searching for dark matter with a spin-based interferometer. Nat Commun 16, 4953 (2025). https://doi.org/10.1038/s41467-025-60178-6
Received:
Accepted:
Published:
Version of record:
DOI: https://doi.org/10.1038/s41467-025-60178-6












